Daikin Altherma ERLQ004-006-008CA Reference Manual page 68

Low temperature split
Hide thumbs Also See for Altherma ERLQ004-006-008CA:
Table of Contents

Advertisement

12 Troubleshooting
Error code
Detailed error
code
P4
00
U0
00
U2
00
U7
00
UA
00
Error codes of the indoor unit
Error code
Detailed error
code
A1
00
AA
01
UA
00
7H
01
7H
04
7H
05
7H
06
81
01
1
On the home screen of your user inter interface, the following information will be displayed:
Bi-zone kit abnormality
detection
Refer to bi-zone kit manual
Installer reference guide
68
Description
OU: Malfunction of radiating
fin temperature sensor.
Please contact your dealer.
OU: Shortage of refrigerant.
Please contact your dealer.
OU: Defect of power supply
voltage.
Please contact your dealer.
OU: Transmission malfunction
between main CPU- INV CPU.
Please contact your dealer.
OU: Indoor/outdoor combination
problem.
Power reset required.
Description
Zero cross detection problem.
Power reset required.
Please contact your dealer.
Backup heater overheated.
Power reset required.
Please contact your dealer.
Indoor unit, outdoor unit
matching problem.
Power reset required.
Water flow problem.
Auto restart.
Water flow problem during
domestic hot water production.
Manual reset.
Check the domestic hot water
circuit.
Water flow problem during
heating/sampling.
Manual reset.
Check the space heating circuit.
Water flow problem during
defrost.
Manual reset.
Check the plate heat exchanger.
Mixed water thermistor
abnormality.
1
Auto reset.
Error code
Detailed error
code
89
01
8H
00
8H
01
8H
02
8F
00
C0
00
U3
00
81
00
C4
00
80
00
U5
00
U4
00
EC
00
HC
00
CJ
02
H1
00
Description
Heat exchanger frozen.
Abnormal increase outlet
water temperature.
Overheating mixed water circuit.
1
Auto reset.
Overheating mixed water circuit
(thermostat).
1
Auto reset.
Abnormal increase outlet
water temperature (DHW).
Flow sensor malfunction.
Manual reset.
Under floor heating screed
dryout function not completed
correctly.
Leaving water temperature
sensor problem.
Please contact your dealer.
Heat exchanger temperature
sensor problem.
Please contact your dealer.
Returning water temperature
sensor problem.
Please contact your dealer.
User interface
communication problem.
Indoor/outdoor unit
communication problem.
Abnormal increase tank
temperature.
Tank temperature sensor
problem.
Please contact your dealer.
Room temperature sensor
problem.
Please contact your dealer.
External temperature
sensor problem.
Please contact your dealer.
ERLQ004~008CA + EHVZ04+08S18CB
Daikin Altherma – Low temperature split
4P401676-1 – 2015.02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma ehvz08s18cbAltherma ehvz04s18cb

Table of Contents