Field settings table
Breadcrumb
Field code
Setting name
A.8
[C-08]
Which type of external sensor is installed?
A.8
[C-09]
What is the required alarm output contact type?
A.8
[C-0A]
--
A.8
[C-0C]
High electricity price decimal (Do not use)
A.8
[C-0D]
Medium electricity price decimal (Do not use)
A.8
[C-0E]
Low electricity price decimal (Do not use)
A.8
[D-00]
Which heaters are permitted if prefer. kWh rate PS is cut?
A.8
[D-01]
Contact type of preferential kWh rate PS installation?
A.8
[D-02]
Which type of DHW pump is installed?
A.8
[D-03]
Leaving water temperature compensation around 0°C.
A.8
[D-04]
Is a demand PCB connected?
A.8
[D-05]
Is the pump allowed to run if prefer. kWh rate PS is cut?
A.8
[D-07]
--
A.8
[D-08]
Is an external kWh meter used for power measurement?
A.8
[D-09]
Is an external kWh meter used for power measurement?
A.8
[D-0A]
--
A.8
[D-0B]
--
A.8
[D-0C]
What is the high electricity price (Do not use)
A.8
[D-0D]
What is the medium electricity price (Do not use)
A.8
[D-0E]
What is the low electricity price (Do not use)
A.8
[E-00]
Which type of unit is installed?
A.8
[E-01]
Which type of compressor is installed?
A.8
[E-02]
What is the indoor unit software type?
A.8
[E-03]
What is the number of backup heater steps?
A.8
[E-04]
Is the power saving function available on the outdoor unit?
A.8
[E-05]
Can the system prepare domestic hot water?
A.8
[E-06]
Is a DHW tank installed in the system?
A.8
[E-07]
What kind of DHW tank is installed?
A.8
[E-08]
Power saving function for outdoor unit.
A.8
[E-09]
--
A.8
[E-0A]
--
A.8
[E-0B]
Is a bi-zone kit installed?
A.8
[E-0C]
--
A.8
[E-0D]
--
A.8
[F-00]
Pump operation allowed outside range.
A.8
[F-01]
--
A.8
[F-02]
Bottom plate heater ON temperature.
A.8
[F-03]
Bottom plate heater hysteresis.
A.8
[F-04]
Is a bottom plate heater connected?
A.8
[F-05]
--
A.8
[F-06]
--
A.8
[F-09]
Pump operation during flow abnormality.
A.8
[F-0A]
--
A.8
[F-0B]
Close shut-off valve during thermo OFF?
A.8
[F-0C]
--
A.8
[F-0D]
What is the pump operation mode?
4P401673-1 - 2015.04
Range, step
Default value
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/W
0: Normally open
1: Normally closed
0
R/W
0~7
0
R/W
0~7
0
R/W
0~7
0
R/W
0~3
0: None
2: BUH only
R/W
0: No
1: Active open
2: Active closed
R/W
0: No
1: Secondary rtrn
2: Disinf. shunt
R/W
0: Disabled
1: Enabled, shift 2°C (from -2 to 2°C)
2: Enabled, shift 4°C (from -2 to 2°C)
3: Enabled, shift 2°C (from -4 to 4°C)
4: Enabled, shift 4°C (from -4 to 4°C)
R/W
0: No
1: Pwr consmp ctrl
R/W
0: Forced off
1: As normal
R/O
0
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
0
2
R/W
0~49
0
R/W
0~49
0
R/W
0~49
0
R/O
0~5
0: LT split
R/O
0: 8 (*5)
1: 16 (*6)
R/O
0~1
1: Type 2
R/O
0~2
1: 1 step
R/O
0: No (*6)
1: Yes (*5)
R/W
0: No
1: Yes
R/O
0: No
1: Yes
R/O
0~6
1: Type 2
R/W
0: Disabled (*6)
1: Enabled (*5)
0
0
R/O
0~1
1: Yes
0
0
R/W
0: Disabled
1: Enabled
R/W
20
R/W
3~10°C, step: 1°C
3°C
R/W
2~5°C, step: 1°C
5°C
R/W
0: No
1: Yes
0
0
R/W
0: Disabled
1: Enabled
0
R/W
0: No
1: Yes
R/W
1
R/W
0: Continuous
1: Sample
2: Request
Installer setting at variance with
default value
Date
Value
(*5) *04/08*