HIKVISION iDS-9632NXI-I8/16S User Manual page 130

Ds-9600ni-i8 series
Hide thumbs Also See for iDS-9632NXI-I8/16S:
Table of Contents

Advertisement

Step 4 Select Trigger Channel tab and select one or more channels which will start to
record/capture or become full-screen monitoring when an external alarm is input, and click
Apply to save the settings.
Step 5 Select Arming Schedule tab to set the arming schedule of handling actions.
Choose one day of a week and Max. eight time periods can be set within each day, and click
Apply to save the settings.
Time periods shall not be repeated or overlapped.
Repeat the above steps to set up arming schedule of other days of a week. You can also use
Copy button to copy an arming schedule to other days.
Step 6 Select Linkage Action tab to set up alarm response actions of the alarm input (please refer to
Chapter Setting Alarm Response Actions).
Step 7 If necessary, select PTZ Linking tab and set PTZ linkage of the alarm input.
Set PTZ linking parameters and click OK to complete the settings of the alarm input.
Make sure the PTZ or speed dome connected supports PTZ linkage.
Network Video Recorder User Manual
Figure 9-6 Set Arming Schedule of Alarm Input
129

Advertisement

Table of Contents
loading

Table of Contents