5.8.3 Control of clock timer

Table 5.8.3.1 shows the clock timer control bits.
Address Bit
Name
00FF40 D7
D6
FOUT2
D5
FOUT1
D4
FOUT0
D3
FOUTON
D2
WDRST
D1
TMRST
D0
TMRUN
00FF41 D7
TMD7
D6
TMD6
D5
TMD5
D4
TMD4
D3
TMD3
D2
TMD2
D1
TMD1
D0
TMD0
00FF20 D7
PK01
D6
PK00
D5
PSIF1
D4
PSIF0
D3
PSW1
D2
PSW0
D1
PTM1
D0
PTM0
00FF22 D7
D6
ESW100
D5
ESW10
D4
ESW1
D3
ETM32
D2
ETM8
D1
ETM2
D0
ETM1
00FF24 D7
D6
FSW100
D5
FSW10
D4
FSW1
D3
FTM32
D2
FTM8
D1
FTM2
D0
FTM1
E0C88832/88862 TECHNICAL MANUAL
5 PERIPHERAL CIRCUITS AND THEIR OPERATION (Clock Timer)
Table 5.8.3.1 Clock timer control bits
Function
FOUT frequency selection
FOUT2
FOUT1
FOUT0
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
FOUT output control
Watchdog timer reset
Clock timer reset
Clock timer Run/Stop control
Clock timer data
1 Hz
Clock timer data
2 Hz
Clock timer data
4 Hz
Clock timer data
8 Hz
Clock timer data
16 Hz
Clock timer data
32 Hz
Clock timer data
64 Hz
Clock timer data
128 Hz
K00–K07 interrupt priority register
Serial interface interrupt priority register
Stopwatch timer interrupt priority register
Clock timer interrupt priority register
Stopwatch timer 100 Hz interrupt enable register
Stopwatch timer 10 Hz interrupt enable register
Stopwatch timer 1 Hz interrupt enable register
Clock timer 32 Hz interrupt enable register
Clock timer 8 Hz interrupt enable register
Clock timer 2 Hz interrupt enable register
Clock timer 1 Hz interrupt enable register
Stopwatch timer 100 Hz interrupt factor flag
Stopwatch timer 10 Hz interrupt factor flag
Stopwatch timer 1 Hz interrupt factor flag
Clock timer 32 Hz interrupt factor flag
Clock timer 8 Hz interrupt factor flag
Clock timer 2 Hz interrupt factor flag
Clock timer 1 Hz interrupt factor flag
1
Frequency
f
/ 1
OSC1
f
/ 2
OSC1
f
/ 4
OSC1
f
/ 8
OSC1
f
/ 1
OSC3
f
/ 2
OSC3
f
/ 4
OSC3
f
/ 8
OSC3
On
Reset
Reset
Run
High
PK01
PK00
PSIF1
PSIF0
PSW1
PSW0
PTM1
PTM0
1
1
1
0
0
1
0
0
Interrupt
enable
(R)
Interrupt
factor is
generated
(W)
Reset
EPSON
0
SR R/W
"0" when being read
0
R/W
0
R/W
This is just R/W
register on
E0C88862.
0
R/W
0
R/W
Off
W
No operation
Constantly "0" when
W
No operation
being read
0
R/W
Stop
0
R
0
R
0
R
0
R
Low
0
R
0
R
0
R
0
R
0
R/W
0
R/W
0
R/W
Priority
0
R/W
level
Level 3
0
R/W
Level 2
0
R/W
Level 1
Level 0
0
R/W
0
R/W
"0" when being read
0
R/W
0
R/W
0
R/W
Interrupt
0
R/W
disable
0
R/W
0
R/W
0
R/W
"0" when being read
0
R/W
(R)
0
R/W
No interrupt
0
R/W
factor is
0
R/W
generated
0
R/W
(W)
0
R/W
No operation
0
R/W
Comment