Test And Adjusting Surface Burner Flame; Test And Adjust Oven Burner Flame - Amana rs2310004-aro3100 Service

Manual clean gas ranges
Table of Contents

Advertisement

Installation Instructions Sealed Burner
Test and Adjust Surface Burner Flame
!
WARNING
To avoid electric shock that can cause personal injury
or death, disconnect main electrical supply to range
before servicing.
Turn on burner. See Operating Surface Burners section
for burner operating instructions. Surface burner should
ignite within 4 seconds. Properly adjusted surface
burner flames are clean and blue with a distinct inner
cone approximately ¼ inch to ½ inch long. Some yellow
flame is normal when burning LP/Propane.
• If burner flame is blowing or noisy, reduce airflow to
burner.
• If burner flame does not hold its shape, increase
airflow to burner.
Burner
A—¼ inch to ½ inch long
Adjusting Air Shutter
1. Remove 4 burner control knobs from range.
• Exposes 2 screws on burner control panel.
2. Remove 2 screws from burner control panel.
• Panel drops slightly after screws are removed.
3. Grasp bottom of burner control panel, gently lift and
pull out panel until clear of burner valve stems.
• After burner control panel clears valve stems,
continue to roll panel until free from range. Set
aside. See Pivot Point in figure.
• Gas valve and orifice hood are visible after burner
control panel is removed.
A
D
A—Burner Control Knob
B—Pivot Point
C—Burner Control Panel
D—Screw
A
B
C
4. Slide air shutter open or closed depending on
appearance of burner flame.
• If flame is yellow and does not hold its shape,
open air shutter.
• If flame is blowing or noisy, close air shutter.
5. Reassemble burner control panel.

Test and Adjust Oven Burner Flame

Turn on oven burner. See "Baking" section for oven
burner operating instructions. Properly adjusted oven
burner flames are blue with a distinct deep blue inner
cone approximately ½ inch long. When using natural
gas, flame should not have any yellow flame when
burning. Some yellow flame when burning LP\propane
gas is normal.
Flame should not be visible in the oven cavity when
burning and should not extend into the oven cavity
beyond the removable oven bottom.
• If burner flame is blowing or noisy, reduce airflow to
burner.
• If burner flame is yellow and does not hold its shape,
increase airflow to burner.
Adjust Oven Burner Flame
1. Check that oven temperature knob is in OFF
position.
2. Open broiler door and remove broiler pan, grid, and
rack.
3. Through rectangular hole in rear of broiler cavity,
loosen air shutter lock screw and open or close air
shutter.
• Tighten air shutter lock screw after adjusting.
A
B
A—Air Shutter Lock Screw
B—Air Shutter
4. Repeat test if necessary.
5. Replace broiler pan, grid, and rack.
27
Close
Open
Open
Close
RS2310004 Rev. 1

Advertisement

Table of Contents
loading

Table of Contents