Installation Instructions Sealed Burner

Gas Supply Location

Gas supply must be located in the shaded area shown.
Gas connection must not interfere with the electrical
connection.
A
B
A—26 inches
B—20 inches
C—2¼ inches
D—4 inches
E—6 inches

Gas Supply Pressure

!
CAUTION
To avoid property damage, maximum gas supply
pressure must not exceed 14" WCP.
• Appliance and individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of ½ psig (3.5kPa) (14" WCP).
• Appliance must be isolated from gas supply piping
system by closing manual shutoff valve during any
pressure testing of the gas supply piping system at
test pressures equal to or less than ½ psig (3.5kPa)
(14" WCP).
• Gas supply pressure for checking regulator setting
must be at least 1" WCP above manifold pressure
shown on rating label.
C
D
E

Pressure Regulator Location

Remove rear cover to expose pressure regulator.
21
RS2310004 Rev. 1