Gas Connection - Amana rs2310004-aro3100 Service

Manual clean gas ranges
Table of Contents

Advertisement

Installation Instructions Sealed Burner
Verifying anti-tip bracket position
1. After range is in place, open broiler door and remove
broiler rack, pan, and grid.
2. Remove screws in front of broiler area on side of
range that antitip bracket is installed.
3. Remove panel and look towards back of oven and
check anti-tip bracket has engaged leveling leg.
4. Reinstall panel after checking anti-tip bracket.
Remove
Screws

Gas Connection

Connect gas supply to regulator using hard pipe or
flexible connector (Check local codes). Pressure
regulator supplied with this appliance has a ½ inch NPT
female connection. If gas union is used, remove storage
drawer, slide range into place, and connect union.
• A manual shutoff, not supplied with range, must be
installed in an accessible location outside of range.
• Use joint compound that is resistant to action of
propane gas on all male pipe threads.
• Use supplied pressure regulator only.
• Do not overtighten gas fitting when attaching to
pressure regulator. Overtightening may crack
regulator.
• Support pressure regulator with wrench when installing
gas fitting.
!
WARNING
To avoid property damage or personal injury, only use
a new flexible connector that is AGA/CGA design
certified.
• Refer to National Fuel Gas Code or local codes for
supply pipe size requirements, to assure sufficient gas
is supplied to the unit.
• Do not use an old connector.
• Do not reuse a connector after moving appliance.
Remove
Panel
25
A—Regulator
B—Adaptor
C—Flexible Connector
D—Manual Shut Off Valve
F
A—Union
B—Manual Shut Off Valve
C—Reducing Elbow (3/4-inch to 1/2-inch)
D—3/4-inch Stub
E—1/2-inch Nipple
F—Regulator
A
B
C
D
A
B
C
E
D