Electrical connection
Warning!
All electrical work must be carried out by a suitably qualified and authorized electrician. No
alterations or willful changes in the electricity supply should be carried out.
Before attempting the connection, check whether the voltage indicated on the rating plate
corresponds to the actual mains voltage.
Mains lead should be minimum 1.5m long.
Earthing wire should be installed in such manner to be the last one pulled out in case the safety
relief device of the mains lead should fail.
Mains lead behind the oven must be placed in such manner to avoid touching the back panel of
the oven because of the heat it develops during operation.
The cable of correct size rating must be used, cable type H05VV-F 3×1.5m m
wire shall be longer than the other wires.
● The means for disconnection from the supply mains having a contact separation in all poles that
provide full disconnection under over voltage category iii shall be provided in the fixed wiring in
accordance with the wiring rules.
Connection (by authorised electrician)
Using the screwdriver open the connector cover at the rear of the appliance. Release two locks
located at either side of the connector bottom.
Mains lead must be led through the relief safety device, protecting the mains lead cable from
disconnection.
Tighten the relief device securely and close the connector cover.
6
2
. The grounding