Exception Handler - Panasonic PN28160K Operation Manual

M16eg
Hide thumbs Also See for PN28160K:
Table of Contents

Advertisement

4.9.4. Exception Handler

On the Switch Tools Configuration Menu, pressing "x" opens the Exception
Handler screen, as shown in Fig. 4-9-6. On this screen, you can configure the
exception handling operations.
PN28160K Local Management System
Switch Tools Configuration -> Exception Handler
Exception Handler:
Exception Handler Mode:
-------------------------------- <COMMAND> -----------------------------------
Enable/Disable E[x]ception Handler
Set Exception Handler [M]ode
[Q]uit to previous menu
Command>
Enter the character in square brackets to select option
Screen Description
Exception Handler
Shows the status of exception handler.
The factory default setting is "Disabled."
Enabled
Disabled
Exception Handler
Shows the method of exception handler.
Mode
Debug Message
System Reboot
Disabled
Debug Message
Fig. 4-9-6 Exception Handler
Exception handler is enabled.
Exception handler is disabled.
When the Switching Hub detects exception
handler, a debug message is displayed on the
console screen.
When the Switching Hub detects exception
handler, the system automatically starts
rebooting.
241

Advertisement

Table of Contents
loading

Table of Contents