Exception Handler - Panasonic PN28058 Operation Manual For Cli

Layer 2 switching hub
Table of Contents

Advertisement

9. Exception Handler

Configure reboot types and execute reboot in "Global configuration mode."
Exception handler enable command
Global configuration mode
Exception handler disable command
Global configuration mode
Exception handler configuration command
Global configuration mode
Exception handler configuration display command
Privileged mode
M8eGLPWR+> enable
M8eGLPWR+# configure
M8eGLPWR+(config)# exception-handler enable
M8eGLPWR+(config)# exception-handler mode both
M8eGLPWR+(config)# end
M8eGLPWR+# show exception-handler
Exception Handler:
Exception Handler Mode:
M8eGLPWR+#
Fig. 9-1 Display of the exception handler configuration
exception-handler enable
no exception-handler enable
exception-handler mode
{ debug-message | system-reboot | both }
show exception-handler
Enabled
Debug Message & System Reboot