Parameter list
Parameter
Function
800
Refer to Pr.80.
——
859
Refer to Pr.84.
——
872
Refer to Pr.251.
——
Regeneration
avoidance
882
operation
selection
Regeneration
883
avoidance
operation level
Regeneration
avoidance
885
compensation
frequency limit
value
Regeneration
886
avoidance voltage
gain
Regeneration
avoidance
665
frequency gain
888
Free parameter 1
889
Free parameter 2
C0
FM terminal
(900)
calibration
C2(902)
to
C7(905)
Refer to Pr. 125 and Pr. 126.
——
C22(922)
to
C25(923)
990
PU buzzer control
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/FR-PU07).
94
Incre-
Initial
Name
ments
Value
1
0
400VDC/
0.1V
780VDC
*1
0.01Hz
6Hz
0.1%
100% 0 to 200%
0.1%
100% 0 to 200%
1
9999
1
9999
1
1
Range
Description
0
Regeneration avoidance function invalid
Regeneration avoidance function is always
1
valid
Regeneration avoidance function is valid
2
only during a constant speed operation
Bus voltage level at which regeneration
avoidance operates. When the bus voltage
level is set to low, overvoltage error will be
less apt to occur. However, the actual
deceleration time increases.
300 to
The set value must be higher than the
800V
"power supply voltage x
*1
Differs according to the voltage class
(100V, 200V/400V)
*2
For Single-phase 100V power input model,
power input voltage
Limit value of frequency which rises at
0 to 10Hz
activation of regeneration avoidance
function.
9999
Frequency limit invalid
Responsiveness at activation of
regeneration avoidance.
A larger setting of Pr. 886 will improve
responsiveness to the bus voltage change.
However, the output frequency could
become unstable.
When vibration is not suppressed by
decreasing the Pr. 886 setting, set a
smaller value in Pr. 665.
Parameters for your own purposes.
0 to 9999
Used for maintenance, management, etc.
by setting a unique number to each
inverter when multiple inverters are used.
Data is held even if the inverter power is
0 to 9999
turned off.
Calibrates the scale of the meter
connected to terminal FM.
0
Without buzzer
1
With buzzer
Param
Param
eter
eter
Copy
Clear
".*2
2
x 2 x
2
All
Param
eter
Clear
×
×
×
×
×