Download  Print this page

Operation Panel Display Is Not Operating; Motor Current Is Too Large - Mitsubishi Electric FR-E700 Basic Instruction Manual

Hide thumbs

Advertisement

4.6.10 Operation panel display is not operating

Check
points
Main
Wiring or installation is improper.
Circuit
Main
Circuit
Power is not input.
Control
Circuit
Command sources at the PU operation mode is not at
Parameter
the operation panel.
Setting
(None of the operation mode displays (
is lit.)

4.6.11 Motor current is too large

Check
points
Torque boost (Pr. 0, Pr. 46) setting is improper under V/F
control, so the stall prevention function is activated.
V/F pattern is improper when V/F control is performed.
(Pr. 3, Pr. 14, Pr. 19)
Parameter
Setting
Stall prevention function is activated due to a heavy
load.
Auto tuning is not performed under Advanced magnetic
flux vector control or General-purpose magnetic flux
vector control.
Possible Cause
Possible Cause
Check first when you have some troubles
Countermeasures
Check for the wiring and the installation.
Make sure that the connector is fitted securely across
terminal P/+ and P1.
Input the power.
Check the setting of Pr. 551 PU mode operation command
source selection.
(If parameter unit(FR-PU04/FR-PU07) is connected
)
while Pr. 551 = "9999" (initial setting), all the operation
mode displays (
Countermeasures
Increase/decrease Pr. 0 Torque boost setting value by
0.5% increments to the setting.
Set rated frequency of the motor to Pr. 3 Base frequency.
Use Pr. 19 Base frequency voltage to set the base voltage
(e.g. rated motor voltage).
Change Pr. 14 Load pattern selection according to the load
characteristic.
Reduce the load weight.
Set Pr. 22 Stall prevention operation level higher according
to the load. (Setting Pr. 22 too large may result in
frequent overcurrent trip (E.OC ).)
Check the capacities of the inverter and the motor.
Perform offline auto tuning.
Refer
to
page
9
9
) turn OFF.)
Refer
to
page