Mitsubishi Electric FR-E700 Basic Instruction Manual page 99

Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter list
Parameter
Function
Earth (ground)
249
fault detection at
start
250
Stop selection
Output phase loss
251
protection
selection
Input phase loss
protection
872
selection
Life alarm status
255
display
Inrush current
256
limit circuit life
display
Control circuit
257
capacitor life
display
Main circuit
258
capacitor life
display
Main circuit
259
capacitor life
measuring
90
Incre-
Initial
Name
ments
Value
1
0
0.1s
9999
1
1
1
1
1
0
1%
100% (0 to 100%)
1%
100% (0 to 100%)
1%
100% (0 to 100%)
1
0
Range
Description
0
Without ground fault detection
1
With ground fault detection
The motor is coasted
to a stop when the
0 to 100s
preset time elapses
after the start signal
is turned OFF.
The motor is coasted
1000 to
to a stop (Pr. 250 -
1100s
1000)s after the start
signal is turned OFF.
9999
When the start signal
is turned OFF, the
motor decelerates to
stop.
8888
0
Without output phase loss protection
1
With output phase loss protection
Without input phase
0
loss protection
With input phase loss
1
protection
Displays whether the control circuit
capacitor, main circuit capacitor, cooling
(0 to 15)
fan, and each parts of the inrush current
limit circuit has reached the life alarm
output level or not. (Reading only)
Displays the deterioration degree of the
inrush current limit circuit. (Reading only)
Displays the deterioration degree of the
control circuit capacitor. (Reading only)
Displays the deterioration degree of the
main circuit capacitor. (Reading only)
The value measured by Pr. 259 is
displayed.
Setting "1" and switching the power supply
OFF starts the measurement of the main
circuit capacitor life.
0, 1
When the Pr. 259 value is "3" after
powering ON again, the measuring is
completed.
Displays the deterioration degree in Pr. 258.
Param
Param
eter
eter
Copy
Clear
STF signal: Forward
rotation start
STR signal: Reverse
rotation start
STF signal: Start
signal
STR signal:
Forward/reverse
signal
STF signal: Forward
rotation start
STR signal: Reverse
rotation start
STF signal: Start
signal
STR signal:
Forward/reverse
signal
Available only for
the three-phase
power input
specification model.
×
×
×
×
All
Param
eter
Clear
×
×
×
×
×
×
×
×