Specifying an edge node
When you configure an edge node, you must configure the primary ring before configuring the
subrings.
To specify an edge node:
Step
1.
Enter system view.
2.
Enter RRPP domain
view.
3.
Specify the current
device as a master node
or transit node of the
primary ring, and
specify the primary port
and the secondary port.
4.
Specify the current
device as the edge node
of a subring, and specify
the edge port.
Specifying an assistant edge node
When you configure an assistant edge node, you must configure the primary ring before configuring
the subrings.
To specify an assistant edge node:
Step
1.
Enter system view.
2.
Enter RRPP domain view.
3.
Specify the current device
as a master node or
transit node of the primary
ring, and specify the
primary port and the
secondary port.
4.
Specify the current device
as the assistant edge
node of the subring, and
specify an edge port.

Activating an RRPP domain

Before you activate an RRPP domain on the current device, enable the RRPP protocol and RRPP
rings for the RRPP domain on the current device.
Follow these guidelines when you activate an RRPP domain:
Before you enable subrings on a device, you must enable the primary ring. Before you disable
the primary ring on the device, you must disable all subrings. Otherwise, the system displays
error prompts.
To prevent Hello packets of subrings from being looped on the primary ring, enable the primary
ring on its master node first. Then enable the subrings on their separate master nodes.
Perform this task on all nodes in the RRPP domain.
Command
system-view
rrpp domain domain-id
ring ring-id node-mode { master |
transit } [ primary-port interface-type
interface-number ] [ secondary-port
interface-type interface-number ] level
level-value
ring ring-id node-mode edge
[ edge-port interface-type
interface-number ]
Command
system-view
rrpp domain domain-id
ring ring-id node-mode { master |
transit } [ primary-port interface-type
interface-number ] [ secondary-port
interface-type interface-number ] level
level-value
ring ring-id node-mode
assistant-edge [ edge-port
interface-type interface-number ]
56
Remarks
N/A
N/A
By default, the device is not a
node of the RRPP ring.
By default, the device is not a
node of the RRPP ring.
Remarks
N/A
N/A
By default, the device is not a
node of the RRPP ring.
By default, the device is not a
node of the RRPP ring.

Hide quick links: