Cfd Configuration Example - HPE FlexFabric 5700 Series Configuration Manual

Hide thumbs Also See for FlexFabric 5700 Series:
Table of Contents

Advertisement

Purpose
associated with the status of the specified port.
Display the one-way DM result on the specified
MEP.
Display LTR information received by a MEP.
Display the content of the LTR messages received
as responses to the automatically sent LTMs.
Display MD configuration information.
Display the attribute and running information for the
MEPs.
Display MEP list in a service instance.
Display MP information.
Display information about a remote MEP.
Display service instance configuration information.
Display CFD status.
Display the TST result on the specified MEP.
Clear the one-way DM result on the specified MEP.
Clear the TST result on the specified MEP.

CFD configuration example

Network requirements
As shown in
The network comprises five devices and is divided into two MDs: MD_A (level 5) and MD_B
(level 3). All ports belong to VLAN 100, and the MAs in the two MDs all serve VLAN 100.
Assume that the MAC addresses of Device A through Device E are 0010-FC01-6511,
0010-FC02-6512, 0010-FC03-6513, 0010-FC04-6514, and 0010-FC05-6515, respectively.
MD_A has three edge ports: Ten-GigabitEthernet 1/0/1 on Device A, Ten-GigabitEthernet 1/0/3
on Device D, and Ten-GigabitEthernet 1/0/4 on Device E, and they are all inward-facing MEPs.
MD_B has two edge ports: Ten-GigabitEthernet 1/0/3 on Device B and Ten-GigabitEthernet
1/0/1 on Device D, and they are both outward-facing MEPs.
In MD_A, Device B is designed to have MIPs when its port is configured with low level MEPs.
Port Ten-GigabitEthernet 1/0/3 is configured with MEPs of MD_B, and the MIPs of MD_A can
be configured on this port. You should configure the MIP generation rule of MD_A as explicit.
The MIPs of MD_B are designed on Device C, and are configured on all ports. You must
configure the MIP generation rule as default.
Configure CC to monitor the connectivity among all the MEPs in MD_A and MD_B. Configure
LB to locate link faults, and use the AIS and EAIS functions to suppress the error alarms that
are reported.
After the status information for the entire network is obtained, use LT, LM, one-way DM,
two-way DM, and TST to detect link faults.
Figure
5:
Command
interface-type interface-number ]
display cfd dm one-way history
[ service-instance instance-id [ mep mep-id ] ]
display cfd linktrace-reply [ service-instance
instance-id [ mep mep-id ] ]
display cfd linktrace-reply auto-detection [ size
size-value ]
display cfd md
display cfd mep mep-id service-instance
instance-id
display cfd meplist [ service-instance instance-id
display cfd mp [ interface interface-type
interface-number ]
display cfd remote-mep service-instance
instance-id mep mep-id
display cfd service-instance [ instance-id ]
display cfd status
display cfd tst [ service-instance instance-id [ mep
mep-id ] ]
reset cfd dm one-way history [ service-instance
instance-id [ mep mep-id ] ]
reset cfd tst [ service-instance instance-id [ mep
mep-id ] ]
24