4.1
Access to the technical parameters
Through the REC10 it is possible to access, using the TECHNICAL menu,
a series of parameters that can be programmed to allow you to personalise
the operation of the boiler:
- select MENU on the initial page of the REC10 and press the key
FRI
18/05/2013
MENU
30
INFO
HOT WATER TEMPERATURE
- keep the keys
and
password menu (about 5 sec)
FRI
18/11/2013
SELECT OPTION
- using the keys
and
access the INSTALLER or SERVICE authorisation level, depending on
the level of the tree menu, then press the key
INSERT PASSWORD
- select TECHNICAL with the keys
selection with the key
SELECT OPTION
- access the desired menu and change/view the parameter concerned
(see the menu tree on page 8).
It is possible to return to the start page at any time by keeping the key
"back/cancel" pressed for at least 2 seconds.
PLANT
12:17
1.3 bar
STATE
°C
.3
SET
pressed at the same time to enter the
MENU
12:17
SETTINGS
select the value of the password to
00
and
, confirming the
MENU
SETTINGS
TECHNICAL
5
COMMISSIONING
5.1

Preliminary checks

First ignition is carried out by competent personnel from an authorised
Technical Assistance Service Beretta.
Before starting up the boiler, check:
- that the data of the supply networks (electricity, water, gas) correspond
to the label data
- that the extraction pipes of the flue gases and the air suction pipes are
working correctly
- that conditions for regular maintenance are guaranteed if the boiler is
placed inside or between items of furniture
- the seal of the fuel adduction system
- that the fuel flow rate corresponds to values required by the boiler
- that the fuel supply system is sized to provide the correct flow rate to
the boiler, and that it has all the safety and control devices required by
current regulations
- that the circulator rotates freely because, especially after long periods of
inactivity, deposits and/or debris can prevent free rotation.
Eventual releasing of the circulator shaft
- Insert a screwdriver in the hole (1) of the circulator.
- Press (a) and turn the n° 2 Phillips screwdriver (b) until the release of
the crankshaft.
Perform this operation with extreme caution to avoid damaging the
components.
5.2

Programming the boiler

- Position the system's master switch to the "on" position.
- If necessary set the TIME and DATE setting the HOURS, MINUTES,
DAY, MONTH and YEAR with the keys "up" and "down", confirming
the selection.
ENTER TIME AND DATE
12
18 / 11 / 2013
USE THE ARROWS TO MODIFY
-
Note: it is possible to change the TIME and DATE settings, as well as
LANGUAGE and the duration of the back-lighting, also later by entering
the MENU from the main screen and then selecting SETTINGS.
b
Each time that the boiler is powered an automatic venting cycle is
carried out lasting 2 min. To interrupt the vent cycle, carry out the
procedure explained in the section "5.3 First commissioning" .
- Set the boiler to OFF
from REC10 selecting the STATE menu and
then BOILER.
a
1
TIME & DATE
:
17
ENGLISH
b
13