Continue with the configuration as follows:
- access the technical parameters as explained in the section "4.1 Access
to the technical parameters" , using the password SERVICE
- select PARAMETERS with the "up" and "down" keys, confirming the
selection
- next change the following parameters:
ENABLE FILLING: set to 1.
Then proceed with the reprogramming of the boiler, carrying out the
operations described in the section "5.2 Programming the boiler" .
5.21 Replacing the REC10 MASTER
b
The system's configuration operations need to be carried out by
professionally qualified personnel of the Technical Assistance Centre.
When replacing the REC10 MASTER, at the subsequent restart it displays
an initial screen with the firmware revision.
Pressing "ok" starts a guided procedure for configuring the system, see
section "5.20 System configuration" . Follow the procedure and carry out the
FROM AKM type of configuration.
MULTI ZONE CONTROLLER
REC10 V01.26
PRESS ANY KEY
5.22 Replacing the AKM01 board
The configuration operations should be carried out by professionally qualified
personnel of the Technical Assistance Centre. The systems continually
carries out a consistency control between the saved configuration data on
the AKM01 electronic board and those saved in the REC10; therefore, when
replacing the AKM01 electronic board, it can happen that the system detects
an inconsistency between the data saved on the AKM01 and that in the
REC10. In this case, the latter will ask the user which of the two configurations
is to be considered valid; selecting to recuperate the configuration from the
REC10 itself it is possible to avoid reconfiguring the machine:
- select REC10 with the "up" and "down" keys, confirming the selection.
5.23 Parameters combustion check
Although the parameters referring to the new combustion control
system ACC (Activate Combustion Control) are preset in the factory, the
simultaneous replacement of both electronics boards (AKM and REC 10
MASTER) could make necessary to re-programming these parameters.
- Access the technical parameters as explained in the section "4.1 Access
to the technical parameters" setting the password SERVICE
- Select COMBUSTION CHECK with the "up" and "down" keys,
confirming the selection
26
TO CONTINUE
SELECT THE TYPE
OF CONFIGURATION
FROM AKM
NEW
SELECT THE TYPE
OF CONFIGURATION
FROM AKM
REC10
EXHAUST PROBE RESET
ALARM HISTORY
COMBUSTION CHECK
SERVICE
- Select GAS TYPE
- Set this parameter depending on the type of gas of the boiler. The values
for this parameter are NG = NATURAL GAS - LPG = LPG
COMBUSTION CHECK
BOILER TYPE
COMBUSTION OFFSET
SERVICE
- Select BOILER TYPE
- Set this parameter depending on the type of boiler as shown in the table
BOILER TYPE
SERVICE
EXCLUSIVE 25C n
EXCLUSIVE 30C n
- Select COMBUSTION OFFSET.
It may be necessary to program this parameter in case of a maintenance on
the AKM board rather than on the detection electrode or the burner, in the
case where, after the operation, the combustion values did not fall within
predetermined values.
COMBUSTION OFFSET
SERVICE
TECHNICAL
PARAMETERS
VENT CYCLE
GAS TYPE
A
B
C
BOILER TYPE
A
B
RESTORE
RESET