Beretta EXCLUSIVE C Installer And User Manual page 39

Hide thumbs Also See for EXCLUSIVE C:
Table of Contents

Advertisement

EXCLUSIVE 25C n
Seasonal space heating energy efficiency
class
Parameter
Rated heat output
For boiler space heaters and boiler combination heaters:
useful heat output
At rated heat output and high-
temperature regime (*)
At 30% of rated heat output and
low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In Stand-by mode
For combination heaters:
Declared load profile
Daily electricity consumption
Annual electricity consumption
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return
temperature (at heater inlet).
EXCLUSIVE 30C n
Seasonal space heating energy efficiency
class
Parameter
Rated heat output
For boiler space heaters and boiler combination heaters:
useful heat output
At rated heat output and high-
temperature regime (*)
At 30% of rated heat output and
low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In Stand-by mode
For combination heaters:
Declared load profile
Daily electricity consumption
Annual electricity consumption
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return
temperature (at heater inlet).
A
Symbol
Value
Unit
Prated
18
kW
P4
17.6
kW
P1
5.9
kW
elmax
28.0
W
elmin
14.0
W
PSB
3.0
W
XL
Qelec
0.127
kWh
AEC
28
kWh
A
Symbol
Value
Unit
Prated
23
kW
P4
23.4
kW
P1
7.8
kW
elmax
37.0
W
elmin
14.0
W
PSB
3.0
W
XL
Qelec
0.167
kWh
AEC
37
kWh
Water heating energy efficiency
class
Parameter
Seasonal space heating energy
efficiency
For boiler space heaters and boiler combination heaters:
useful efficiency
At rated heat output and high-
temperature regime (*)
At 30% of rated heat output and
low-temperature regime (**)
Other parameters
Stand-by heat loss
Pilot flame energy consumption
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxides
Water heating energy efficiency
Daily fuel consumption
Annual fuel consumption
Water heating energy efficiency
class
Parameter
Seasonal space heating energy
efficiency
For boiler space heaters and boiler combination heaters:
useful efficiency
At rated heat output and high-
temperature regime (*)
At 30% of rated heat output and
low-temperature regime (**)
Other parameters
Stand-by heat loss
Pilot flame energy consumption
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxides
Water heating energy efficiency
Daily fuel consumption
Annual fuel consumption
ENGLISH
A
Symbol
Value
Unit
ηs
93
%
η4
87.4
%
η1
98.0
%
Pstby
42.0
W
Pign
-
W
QHE
33
GJ
LWA
51
dB
NOx
44
mg/kWh
ηwh
86
%
Qfuel
22.796
kWh
AFC
17
GJ
A
Symbol
Value
Unit
ηs
93
%
η4
87.3
%
η1
97.7
%
Pstby
42.0
W
Pign
-
W
QHE
43
GJ
LWA
53
dB
NOx
33
mg/kWh
ηwh
85
%
Qfuel
22.960
kWh
AFC
17
GJ
39

Hide quick links: