Beretta EXCLUSIVE C Installer And User Manual page 5

Hide thumbs Also See for EXCLUSIVE C:
Table of Contents

Advertisement

The boiler is a C-type appliance (with airtight chamber), and must therefore
have a safe connection to the flue gas discharge pipe and to the combustion
air suction pipe; these both carry their contents outside, and are essential
for the operation of the appliance.
Both concentric and twin terminals are available.
Suction/discharge pipes length table
Flue gases pipe Ø 80 mm
("forced open" installation)
(type B23P-B53P)
Concentric pipe
Ø 60-100 mm (horizontal)
Concentric pipe
Ø 60-100 mm (vertical)
Concentric pipe
Ø 80-125 mm
Twin pipe Ø 80 mm
b
"Straight length" means with terminals and joints but without bends.
b
The boiler is supplied without the flue gas outlet/air suction kit, since
it is possible to use the accessories for condensing appliances that
better adapt to the installation characteristics (see catalogue).
b
The maximum lengths of the pipes refer to the flue accessories
available in the catalogue.
b
It is compulsory to use specific pipes.
b
The non insulated flue gas outlet pipes are potential sources of
danger.
b
The use of a longer pipe causes a loss of output of the boiler
b
Make sure the flue gas discharge pipe is tilted 3° towards the boiler.
b
As envisaged by current legislation, the boiler is designed to take
in and dispose of flue gas condensate and/or meteoric water
condensate deriving from the flue gas discharge system using its
own siphon.
b
If a condensate relaunch pump is installed, check the technical
data (provided by the manufacturer) regarding output, to ensure it
operates correctl.
"Forced open" Installation (type B23P/B53P)
In this configuration the boiler is connected to the ø 80 mm flue gases
discharge pipe by means of an adaptor.
- Position the adaptor so that the Ø 60 pipe goes fully into the flue gases
turret of the boiler.
- Once positioned, make sure that the 4 notches (A) on the flange connect
to the groove (B) on the Ø100 of the adaptor.
- Fully tighten the two locking terminals of the flange (C) so the adaptor
itself is restrained.
Concentric pipes (ø 60-100 mm)
- Position the bend so that the Ø 60 pipe goes fully into the flue gases
turret of the boiler.
- Once positioned, make sure that the 4 notches (A) on the flange connect
to the groove (B) on the Ø100 of the bend.
- Fully tighten the two locking terminals of the flange (C) so the bend itself
is restrained.
Twin pipes (ø 80 mm) - see graphs fig. 18
The combustion air suction pipe should be selected from the two inputs,
remove the closing plug fixed with the screws and fix the specific air
deflector.
- Position the adaptor on the flue gases pipe so that the Ø 60 pipe goes
fully into the flue gases turret of the boiler
- Once positioned, make sure that the 4 notches (A) on the flange connect
to the groove (B) on the Ø100 of the adaptor.
- Fully tighten the two locking terminals of the flange (C) so the adaptor
itself is restrained.
Concentric pipes (ø 80-125 mm)
- Position the adaptor so that the Ø60 pipe goes fully into the flue turret
of the boiler.
- Once positioned, make sure that the 4 notches (A) on the flange connect
to the groove (B) on the Ø100 of the adaptor.
- Fully tighten the two locking terminals of the flange (C) so the adaptor
itself is restrained.
- Then fit the Ø 80-125 adaptor kit on the vertical fitting.
Maximum straight
Pressure drop
length
bend
25C n
30C n
45°
125 m
90 m
1 m
10 m
10 m
1,3 m
11 m
11 m
1,3 m
25 m
25 m
1 m
70+70 m 50+50 m
1 m
Twin pipes ø 80 with ducting Ø50 - Ø60 - Ø80 (fig. 15a)
Thanks to the boiler characteristics, a flue gas discharge pipe ø 80 can
be connected to the ducting ranges Ø50 - Ø60 - Ø80.
b
For the ducting, you are advised to make a project calculation in
order to respect the relevant standards in force.
The table shows the standard configurations allowed.
Table of standard pipe configurations (*)
bend
Air suction
90°
1,5 m
Flue gas discharge
1,6 m
1,6 m
(*) Use flue gas system accessories in plastic (PP) for condensing boilers:
Ø50 and Ø80 H1 class and Ø60 P1 class.
1,5 m
The boilers are factory set to:
1,5 m
25C n: 5.600 r.p.m. (CH) and 7.900 r.p.m. (DHW) and the maximum length
that can be reached is 6m for the ø 50 pipe, 21m for the ø 60 pipe and 115m
for the ø 80 pipe.
30C n: 6.500 r.p.m. (CH) and 7.900 r.p.m. (DHW) and the maximum length
that can be reached is 4m for the ø 50 pipe, 16m for the ø 60 pipe and 83m
for the ø 80 pipe.
Should it be necessary to achieve greater lengths, compensate the pres-
sure drop with an increase in the r.p.m.of the fan, as shown in the adjust-
ments table, to ensure the rated heat input.
b
The minimum calibration is not modified.
Adjustments table
Maximum number
of fan rotations
CH
5.600
5.600
5.700
5.700
5.800
5.900
25C n
6.000
6.100
6.200
6.200
6.300
6.400
6.500
6.600
6.700
6.800
6.900
30C n
7.000
7.100
7.200
7.300
7.400
(*)
Maximum installable length ONLY with exhaust pipes in H1 class.
Configurations Ø50 or Ø60 or Ø80 show test data verified in the laboratory.
In the case of installations that differ from those indicated in the "standard
configuration" and "adjustments" tables, refer to the equivalent linear
lengths below.
b
In any case, the maximum lengths declared in the booklet are
guaranteed, and it is essential not to exceed them.
1 bend 90° ø 80
4,5m pipe ø 80
1 bend 90° ø 80
4,5m pipe ø 80
Reduction from ø 80 to ø50, from ø 80 to ø 60
Stack base bend 90°, ø 50 or ø 60 or ø 80
For ducting pipe lengths see table
Ducting pipes
maximum length (m)
r.p.m.
DHW
Ø 50
Ø 60
7.900
6
21
8.000
8 (*)
25 (*)
8.100
10 (*)
32 (*)
8.200
12 (*)
35 (*)
8.300
14 (*)
42 (*)
8.400
17 (*)
48 (*)
8.500
19 (*)
53 (*)
8.600
22 (*)
60 (*)
8.700
24 (*)
66 (*)
8.800
26 (*)
71 (*)
8.900
28 (*)
76 (*)
9.000
31 (*)
82 (*)
7.900
4
16
8.000
5 (*)
19 (*)
8.100
7 (*)
24 (*)
8.200
9 (*)
28 (*)
8.300
11 (*)
33 (*)
8.400
13 (*)
37 (*)
8.500
14 (*)
40 (*)
8.600
16 (*)
44 (*)
8.700
17 (*)
48 (*)
8.800
19 (*)
53 (*)
ENGLISH
ΔP at
boiler
output
Ø 80
Pa
115
180
139 (*)
210
175 (*)
255
195 (*)
280
231 (*)
325
263 (*)
365
291 (*)
400
331 (*)
450
363 (*)
490
389 (*)
523
420 (*)
562
452 (*)
601
83
190
103 (*)
225
128 (*)
270
151 (*)
310
174 (*)
350
196 (*)
390
213 (*)
420
236 (*)
460
256 (*)
495
281 (*)
540
5