Fume Inhalation

Remove the person to fresh air. Give artificial respiration or cardiopulmonary resuscitation (CPR) if required. If breathing is difficult, give
oxygen . Obtain immediate medical attention .

SAFETY NOTICE

CAUTION: Use of controls or adjustments, or performance of procedures other than those contained in the operation,
maintenance or any other manual provided with this machine may result in hazardous radiation exposure .
This laser process machine is certified as a CLASS 1 laser product to the requirements of the US Federal Product Performance
Standard for Laser Products contained in the regulations in 21 CFR Subchapter J except for specific deviations described in FDA Laser
Notice #50 .
NOTE: Class 1 laser products are not considered to be hazardous .
This machine incorporates a Class 4 laser and optical system which, by itself, may be hazardous . However, this machine incorporates
a protective housing, laser protective viewing window, and safety interlocks in the machine design such that there is no exposure or
human access to the laser radiation generated by the laser during operation .
All service to the laser process machine, the embedded laser system and optics requiring interlock override shall only be performed
by 3D Systems Corporation service personnel, their authorized agents, or personnel trained by 3D Systems Corporation . The
manufacturer's user information for the incorporated laser products are supplied with this process machine .
UNDER NO CIRCUMSTANCE shall attempts be made by the user to operate the laser with safety interlocks bypassed or tool
removable access panels that allow access to laser radiation removed . Labels are provided on the products that indicate hazards .
Reproductions of these labels and diagrams showing their location are provided in this manual .
The laser should not be operated if the laser protective window material installed onto the front of the process chamber is damaged
or removed . The window material has a measured minimum optical density (OD) of 5+ @ 355nm . Contact the manufacturer for
replacement information .