Operator parameters
28
Name:
1
Index:
1A00h
Meaning:
This parameter defines the process data assignment of the first PDO
that carries data from slave to master. All further informations can be
taken from the description of parameter 1
Name:
HS_SyncToutMode
2281h
Index:
Subindex:
0
Meaning:
Defines the reaction to the SYNC timeout event, 4.3.3
Data length:
1 byte
Coding:
0: Automatic return into normal mode.
1: Change into automatic synchronous mode.
Default value:
1
Note:
A new value takes effect immediately and is stored non-volatile.
Name:
HS_SyncToutDelay
Index:
2282h
Subindex:
0
Meaning:
Here it can be configured how many SYNC events have to be received
until the SYNC timeout-supervising is activated after switching on. This
parameter can be used if the cyclic SYNC events cannot be guaranteed
immediately after switching into the synchronous operating mode.
Data length:
2 byte
Coding:
Number of SYNC events
Default value:
0
Note:
A new value takes effect immediately and is stored non-volatile.