Figure 19: Download Finished Message; Figure 20: Firmware In Port_0 - hilscher netTAP NT 151-RE-RE User Manual

Real-time ethernet gateway
Table of Contents

Advertisement

Firmware recovery
6. Restart netTAP device.
netTAP NT 151­RE­RE | Real­Time Ethernet gateway
DOC150802UM01EN | Revision 1 | English | 2016­07 | Released | Public
Ø Acknowledge the File successfully downloaded message by clicking
the OK button.
Figure 19: Download finished message
Ê The downloaded firmware file should now be displayed under PORT_0:
Figure 20: Firmware in PORT_0
Ø In the menu, choose Connection > Close to close the connection to
the netTAP, then choose File > Exit to close ComProX.
Ø Disconnect the voltage supply from the device, then reconnect it.
Ê After restart, the SYS LED shows steady green light (indicating firmware
is running) and the APL LED shows steady red light (indicating missing
configuration).
ð You have reset the netTAP device to its factory settings. The device
now needs a new configuration with SYCON.net via USB connection.
Instructions for this can be found in the operating instruction manual
Configuration of Gateway and Proxy Devices, DOC081201OIxxEN.
46/81
© Hilscher 2016

Advertisement