2 Initial Settings
2-2-2

Exiting

This section gives procedures to shut down Windows and Real-Time OS (Controller function), and turn
OFF the power supply to the Industrial PC.
Precautions for Safe Use
Before turning OFF the power supply to the Industrial PC, you must ensure that there is no pro-
gram running on Windows, and that it is safe to shut down the system while the current pro-
gram is running.
How to turn OFF the power supply to the Industrial PC depends on the trigger types as follows.
Trigger type
Power button
Input signal from UPS
Shutdown instruction from the
Controller
*1.
You can set the shutdown processing time on the Controller Setup. Refer to the NY-series Industrial Panel PC / Industrial Box PC
Software User's Manual (Cat. No. W558) for details on the settings and shutdown processing.
*2.
Refer to the NY-series Instructions Reference Manual (Cat. No. W560) for details on using the shutdown instruction.
The exiting procedure when the trigger is pressing the power button is given below.
1
Press and release the power button on the Industrial PC within 1 second.
The program running on the Controller is stopped, and the Real-Time OS (Controller function)
is shut down. Then Windows is shut down, and the power supply to the Industrial PC is turned
OFF.
Precautions for Correct Use
When you press the power button for five seconds or longer, the power is compulsory
turned OFF without going through the shutting down process. Be careful to use this pro-
cedure. It may cause a loss of a program running on the Controller or data in a Windows
application.
Additional Information
• You cannot shut down from the Windows start menu.
• Refer to the NY-series Industrial Box PC Hardware User's Manual (Cat. No. W556) or the NY-
series Industrial Panel PC Hardware User's Manual (Cat. No. W557) for details on abnormal
shutdowns by an interruption of power supply when a UPS is not used, or by overheating.
2-2-3

Restarting

The procedures to restart the Industrial PC are given below. The types of restarting depend on what is
restarted as follows. Each is for a different target to restart.
Type
Restarting Windows
Restarting the Controller
2 - 6
Shutting down by pressing the power button on the Industrial PC.
Shutting down with a signal input from UPS to the Industrial PC. The signal input is caused by an inter-
ruption of power supply which is connected to the UPS.
Shutting down in a desired timing when the shutdown instruction is executed in the Controller program.
*2
Restarts only Windows. The Controller is not affected by the Windows restart.
Restarts or resets only the Controller. Windows is not affected by the Controller restart.
NY-series Industrial Panel PC / Industrial Box PC Setup User's Manual (W568)
Description
*1
*1
Description