A-2 Changing the Internal Port Settings

Communications between the Controller and Windows are enabled in the default setting for the inter-
nal ports on the Controller and Windows.
Normally, you do not have to change the internal port setting. However, you may need to change the
initial IP address (192.168.254.***/24) in the following case.
• An IP address on an external network connected to the Industrial PC is the same as a network ad-
dress in the internal network.
This section explains the method and precautions for changing the internal port settings for the Con-
troller and Windows.
When you change the internal port setting for the Controller, you must also change the internal port
setting for Windows to ensure communications between the Controller and Windows.
The procedure to change the settings is given below.
1
Changing Internal Port Setting for Controller
Change the IP address of the internal port for the Controller so that it does not overlap with a
network address used on an external network.
Use the Industrial PC Support Utility or Sysmac Studio to change the internal port setting for
the Controller.
Refer to 4-7 Network Settings for Controller on page 4 - 16 or the Sysmac Studio Version 1
Operation Manual (Cat. No. W504) for details on the changing method.
2
Changing Internal Port Setting for Windows
Change the IP address of the internal port for Windows so that it is the same as the new net-
work address of the internal port for the Controller.
To change the internal port setting for Windows, change the setting of a virtual network adapt-
er. Refer to 3-1 Internal Port Settings on page 3 - 2 for details on virtual network adapters.
3
Changing Virtual SD Memory Card Settings
When a Virtual SD Memory Card is used, the IP address setting for the Virtual SD Memory
Card is updated with the new IP address of the internal port for Windows. Use the Industrial PC
Support Utility or Sysmac Studio to change the Virtual SD Memory Card settings.
Refer to 4-8 Virtual SD Memory Card Settings on page 4 - 18 or the Sysmac Studio Version 1
Operation Manual (Cat. No. W504) for details on the changing method.
Additional Information
When the IP address of the internal port for the Controller is changed, the connection with the
Industrial PC Support Utility is disconnected. In the Network Connection dialog box of the In-
dustrial PC Support Utility, enter the new IP address of the internal port to establish the connec-
tion again.
NY-series Industrial Panel PC / Industrial Box PC Setup User's Manual (W568)
Appendices
A
A - 3