OM 2012
(c)
Meter
switch
(5) may be in any pcsition
except
pointing
straight
DOWN.
'
(2)
Connect
output
cable plug connects
to aircraft
receptacle.
Be sure ctinnectas
are mated fully
and secue
ly.
.
E.
Power Delivery
(Automatic
Voltage
Co&of)
(1)
Place engine-generator
control
switch
(18,
Fig.
1) in Bu I LD-U P-VOLTAGE
pas it ion
momentarily,
then allow
it to position
itself
in GEN
pbsition.
The electric
gov-
erncr will.
immediately
increase engine speed fo 2000 RPM and maintain
it.
(2)
Observe
generator
instruments.
Frequency
meter (1,
Fig.
1) should
indicate
exactly
400 Hr.
Voltmeter
(2) should
indicate
115 V AC when line switch
(6)
is in LINE-TO-NEUTRAL
position.
(3)
The final
step in delivering
power is closing
the load contactor.
When
satisfacto~
frequency
and voltage
values are indicated
by the instruments,
close the load con-
.'
tactor
by momentarily
placing
the load contactor
control
switch
(20) in the-tap
(jprirlg
kxded),
CLOSE
position.
The green indicating
light
(22) should glow at
.
once to indicate
that the foad cantactor
is closed ad
power is available
at the
aircraft.
Ps soon OS the light gbws,
release the switch.
It will
automatically
ret,um to the center ON position.
NOTE:
If the indicating
light
(22) should
"go-out"
as saon as the switch
'
is released,
and no fault
jighis
are ON,
it indicates
that 28.5-V
DC holding
current
is not being supplied
from the aircraft
ta the
plugtinteriock
relay.
Correct
the' condition
and
again operate the
load contactor
control
switch
(20) as above.
.
(4).
It is recommended
that the operator
check output
voltage
and current
in each
of the
three
phases early
in the power delivery
run.
Use the meter switch
(5)
to select
the phose.
Use the line switch
(6) to select
line-to-line
or iine-ta-
neutral
voltage.
if the food
is
changing,
it is goad operating
practice
to ob-
seme the instruments
until
toad conditions
stabilize.
(5)
A condition
of overvoltage,
undervoltage,
under-frequency,
averfrequency,
or
overload
in the output
circuit
will
automatically
open the load contactor
and
turn on the applicable
indicating
light
to signal
the operator
which
of the
abave fau!ts
caused the protective
monito'r system to operate.
After
the fault
has been corrected,
press the reset switch
(7) to turn off the indicating
light
and reset the protective
relay system.
Proceed with
power delivery
by operating
the load contactor
switch.
.I
i
l-3