Hobart 5359D Operation And Maintenance Manual page 27

Engine-driven generator set
Table of Contents

Advertisement

OM 2012
PHYSiCAL
(Bas ic Generator
Set)
Length
Width
(without
tracks)
Height
(without
i ifting
eye)
Weight
(without
tracks )
82 INCHES
(2082.8
MM)
35 INCHES
(889
0 MM)
40 INCHES
(1016.0
MM)
Approx.
3980
POUNDS
(1805
KG)
GENERATOR
Output
power rating
Output
voltage
Rated load capacity
Frequency
(cycles-per-second)
Output
kilowatts
.
Power factor
D*
cycle
Operating
speed at 400 Hz
Gve'rload
capacity
(125%
of rated
load capacity)
90 KVA
115/200
v
260 A
400 Hz
72 KW
0.8
PF
100%
2000
RPM
325 A
GENERATOR
PROTECTIVE
SYSTEM
Overvoltage
relay
trips 130 V to 134 V;resdts
125 V
Undervohage
relay
trips 102 V 0~ below; resets 110 V
Overfrequency
t-e lay
trips 415 Hz to 425 Hz;resets
410 Hz
Underfrequency
relay
trips 375 Hz to 385 Hqresets
385 Hz
Overload
relay
trips 112 KVA
in less than 5 minutes
Undervo itage
time delay
relay
4 to 12 seconds
Specifications
and Capabilities
Figure 2 ( Sheet 1 of 2)
Aug 25 '85
Page 3