Error Code Message Information
PDR1001
PDR1002
PDR1016
PDR1024
PST0128
PST0129
Downloaded from
www.Manualslib.com
Details
The controller detected a drive removal.
Action
If unintended, verify drive installation. Remove and re-seat the indicated disk. If the
issue persists, see
Message
Fault detected on drive <
LCD Message
Fault detected on drive <
Details
The controller detected a failure on the disk and has taken the disk offline.
Action
Re-seat the failed drive. If the issue persists, see
Message A predictive failure detected on drive <
Details
The controller received a SMART error from the drive. The drive is operational but needs
replacement.
Action
The drive will need replacement at the next service window.
number > is removed from disk drive bay < bay >.
Message
Drive <
LCD Message
Drive <
number > removed from disk drive bay < bay >. Check drive.
Details
The controller detected that the drive was removed.
Action
Verify drive installation. Re-seat the failed drive. If the issue persists, see
Message
Drive mismatch detected for drive <
LCD Message Drive mismatch detected for drive <
Details
The installed disk does not meet the array requirements, for example a SATA disk may
not operate in an array containing SAS drives.
Action
Verify that the disk meets the array requirements.
Message
No memory is detected.
LCD Message
No memory is detected. Inspect memory devices.
Details
System BIOS was unable to detect memory in the system .
Action
Re-seat the memory modules. If the issue persists, see
Message
Memory is detected, but is not configurable.
LCD Message Memory is detected, but is not configurable. Check memory devices.
Details
System BIOS detected memory, but was unable to configure the memory for system
operation.
Action
Compare system memory installation to supported system memory configurations.
manuals search engine
Getting
Help.
number > in disk drive bay < bay >.
number > in disk drive bay < bay >. Check drive.
number > in disk drive bay< bay >.
number > in disk drive bay < bay >.
number > in bay < bay >. Install correct drive type.