Error Code Message Information
PSU1203
PSU1204
PWR1001
PWR1002
PWR1003
PWR1004
Downloaded from
www.Manualslib.com
Action
Remove input power and reinstall supply at the next service window.
Message
The power supplies are not redundant.
LCD Message Lost PSU redundancy. Check PSU cables.
Details
The current power operational mode is non-redundant because of a power supply
exception, a power supply inventory change, or a system power inventory change.
Action
Check the event log for power supply failures. Review system configuration and power
consumption.
Message
The power supplies are not redundant. Insufficient resources to maintain normal
operations.
LCD Message PSU redundancy degraded. Check PSU cables.
Details
The current power operational mode is non-redundant because of a power supply
exception, a power supply inventory change, or a system power inventory change.
Action
Check the event log for power supply failures. Review system configuration and power
consumption.
Message
The system performance was degraded.
LCD Message System performance degraded. Check PSUs and system configuration.
Details
To avoid shutdown, system performance has been degraded.
Action
Review system configuration and system logs for thermal or environmental failures and
warnings.
Message The system performance degraded because of thermal protection.
Details
To avoid shutdown, system performance has been degraded.
Action
Review system configuration and system logs for thermal or environmental failures and
warnings.
Message The system performance degraded because cooling capacity has changed.
Details
The current power supply configuration does not meet the platform requirements to enable
redundancy. If a power supply fails the system may shutdown.
Action
If unintended, review system configuration and power consumption and install power
supplies accordingly. Check power supply status for failures.
Message The system performance degraded because power capacity has changed.
Details
The system may power down or operate in a performance degraded state.
Action
Check the event log for power supply failures. Review system configuration and power
consumption and upgrade or install power supplies accordingly.