Error Code Message Information
CPU0805
CPU0806
CPU0816
HWC1001
HWC1002
HWC1005
HWC1006
Downloaded from
www.Manualslib.com
Message The power input for CPU <
attached to the system.
Details
System performance may be degraded or the system may fail to operate.
Action
1. Turn system off and remove input power for one minute.
2. Reapply input power and turn system on.
3. Ensure the processor is seated correctly.
4. If the issue persists, see
number > voltage regulator module is incorrectly configured.
Message
CPU <
number > voltage regulator module incorrectly configured. Check configuration.
LCD Message
CPU <
Details
System performance may be degraded or the system may fail to operate.
Action
Review this manual for proper configuration and installation procedures.
number > voltage regulator module is absent.
Message
CPU <
number > voltage regulator module absent. Check module.
LCD Message
CPU <
Details
System performance may be degraded or the system may fail to operate.
Action
If removal was unintended, check presence and reinstall.
Message
The <
name > is absent.
LCD Message The <
name > is absent. Check hardware.
Details
The absent device may be necessary for proper operation. System functionality may be
degraded.
Action
Reinstall or reconnect the hardware.
Message
The <
name > is disabled.
Action
If device disabled unexpectedly, re-enable device.
Message
The storage adapter is absent.
LCD Message The storage adapter is absent. Check hardware.
Details
The storage adapter may be necessary for proper operation. System functionality may
be degraded.
Action
Install storage adapter.
Message
The storage adapter is disabled.
Action
If adapter disabled unexpectedly, re-enable the storage adapter.