4. Settings
4-3-10. Current value store
This sets whether to display the previous value when the power is turned on again.
When using the master calibration function, a value is not displayed unless the measuring unit goes past a
reference point, and so it will not function even if set to ON.
4-3-11. Flicker control
If the number for the minimum digit of the display value is flickering and unstable, this flickering can be
reduced.
4-3-12. Sleep
The display can be turned off automatically when the measuring unit is not moved and no key operations are
performed for a certain period of time while the power is on. The display is restored whenever the measuring
unit is moved or any key operation is made. The key operation at this time simply restores the display, and
the normal key function is not performed. The display is restored even when the key lock is applied.