2. Name and Function of Each Part

2-1. Front Panel

Some controls are used only when the comparator unit (LZ71-KR) (option) is connected.
(See "9-2. Key Operations" for a detailed description of the keys.)

2-1-1. When used without the comparator

q
No.
Name
q
ABS lamp
w
Counter display
e
RESET key
r
Axis Select key
t
P key
y
key
(Datum Point Value/
Master Calibration Value
Setting key)
u
REF key
i
ABS/INC key
o
SETUP key
!0
HOLD key
LY71
w
e
t
r
Function
Lights on : When displaying absolute value (ABS)
Flashes
: When selecting the axis
Lights off : When displaying incremental value (INC)
A/B
: Measurement value display (current value, peak value)
C
: Measurement value display (current value, peak value)
However, unlike displays A and B, this is a reference
display, so operations to change numerical value
contents are not allowed.
Shows status with alphabetical letters when making mode settings
(See "7. Alarm Display" when an error occurs.)
Resets incremental value to zero
Switches to INC mode when pressed during ABS display.
Selects an axis for the following operations undertaken thereafter
are to the axis
Used to perform numerical value setting operations (preset)
(lamp lights on when selected)
Used to set the datum point (lamp lights on when selected)
Used to set the master calibration value when using the master
calibration function
Used to detect the measuring unit reference point
(lamp lights on when selected)
Used to relocate the master calibration value when using the
master calibration function
Switches between ABS mode and INC mode
Used to start to make various settings
Used when using the hold function (latch/pause) (lamp lights on
when hold function is selected)