Connection - Magnescale LY71 Instruction And Installation Manual

Counter unit
Hide thumbs Also See for LY71:
Table of Contents

Advertisement

3. Installation and Connection

3-2. Connection

Be sure to provide power to the AC adaptor only after all other connections have been made.
• Fasten the connecting cables to stable members to prevent accidental disconnection.
• Be sure to always turn off the AC power to the AC adaptor of the counter unit before connecting or
disconnecting the measuring unit connector or replacing the measuring unit. Do not plug in or unplug the
DC output connector on the counter unit side.
• Do not route connecting cables through the same duct as the machine power line.
• If securing the counter unit in place, secure it to the installed counter bracket.
Counter unit anchor bolts (supplied): M4 × 16 (2)
1
Secure the measuring unit.
2
Connect the measuring unit connector to the measuring unit input on the counter unit rear panel.
3
Install the AC adaptor.
Do not provide power to the AC adaptor in this step.
4
Remove the cable clamp on the counter unit rear panel.
5
Connect the DC output connector to the DC input terminal.
6
Attach the DC output connector cable to the cable clamp removed in step 5, and then secure it in place.
Secure the cable so that excessive force is not applied to the connector.
7
Connect the ground wire.
8
Provide power to the AC adaptor.
<When power is turned on for the first time after factory shipping>
When the power is turned on for the first time, the basic settings must be made before use.
Proceed to "4. Settings".
<When the basic settings have already been completed>
is displayed on the connected displays (1 to 3).
After providing power, perform the basic settings (4-2) to allow operation.
3-2
(E)
LY71