Emerson Unidrive M100 Control User Manual page 83

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M100:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Trip
d.Ch
Drive parameters are being changed
A user action or a file system write is active that is changing the drive parameters and the drive has been commanded to
enable, i.e. Drive Active (10.002) = 1.
97
Recommended actions:
Ensure the drive is not enabled when defaults are being loaded
dEr.E
Derivative file error
Derivative file error with sub-trips:
Sub-trip
246
Recommended actions:
Contact the supplier of the drive.
Unidrive M100 / M101 Control User Guide
Issue Number: 1
Electrical
Getting
installation
started
parameters
Reason
1
The derivative file is missing or is invalid
The derivative file does not match the
2
control board hardware
The derivative file has been changed for a
3
file with a different derivative number.
Basic
Running the
Optimization
motor
Diagnosis
Occurs when the drive powers-up. Load valid derivative file
matching the control board hardware.
Occurs when the drive powers-up. Load valid derivative file
matching the control board hardware.
Occurs when the drive powers-up or the file is
programmed. The file tasks will not run.