Emerson Unidrive M100 Control User Manual page 73

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M100:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Parameter
08.001 Digital I/O 1 State (T10)
08.002 Digital Input 2 State(T11)
08.003 Digital Input 3 State (T12)
08.004 Digital Input 4 State (T13)
08.008 Relay 1 Output State
08.011 Digital I/O 1 Invert (T10)
08.012 Digital Input 2 Invert (T11)
08.013 Digital Input 3 Invert (T12)
08.014 Digital Input 4 Invert (T13)
08.018 Relay 1 Invert
08.020 Digital I/O Read Word
08.021 Digital IO1 Source / Destination A (T10)
08.022 Digital Input 2 Destination A (T11)
08.023 Digital Input 03 Destination A (T12)
08.024 Digital Input 04 Destination A (T13)
08.028 Relay 1 Output Source A
08.031 Digital I/O 01 Output Mode (T10)
08.043 24 V Supply Input State
08.053 24 V Supply Invert
08.063 24 V Supply Input Destination
08.081 DI1 Control (T10)
08.082 DI2 Control (T11)
08.083 DI3 Control (T12)
08.084 DI4 Control (T13)
08.091 DO1 Control
08.098 Relay 1 Control
08.121 DI/O 01 Source / Destination B (T10)
08.122 Digital Input 2 Destination B (T11)
08.123 DI 03 Destination B (T12)
08.124 DI 04 Destination B (T13)
08.128 Relay 01 Source B
RW
Read / Write
RO
Read only
ND
No default value
NC
Not copied
Date
Date parameter
Time Time parameter
Unidrive M100 / M101 Control User Guide
Issue Number: 1
Electrical
Getting
Basic
installation
started
parameters
Range
OL
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Not.Inv (0), InvErt (1)
Not.Inv (0), InvErt (1)
Not.Inv (0), InvErt (1)
Not.Inv (0), InvErt (1)
Not.Inv (0), InvErt (1)
0 to 2048
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
InPut (0), OutPut (1),
Fr (2), PuLSE (3)
Off (0) or On (1)
Not.Inv (0), InvErt (1)
0.000 to 30.999
0 to 21
0 to 21
0 to 21
0 to 21
0 to 20
0 to 20
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
Num Number parameter
PT
Protected parameter
Running the
Optimization
NV Media Card
motor
Default
( )
OL
Not.Inv (0)
Not.Inv (0)
Not.Inv (0)
Not.Inv (0)
Not.Inv (0)
10.003
50 Hz: 6.038
60 Hz: 6.039
50 Hz: 6.030
60 Hz: 6.034
50 Hz: 6.032
60 Hz: 6.031
10.001
OutPut (1)
Not.Inv (0)
0.000
0
0
0
0
0
0
0.000
Bit
Bit parameter
Txt
Text string
RA
Rating dependent
US
User save
Advanced
Diagnostics
parameters
( )
Type
RO
Bit
ND NC PT
RO
Bit
ND NC PT
RO
Bit
ND NC PT
RO
Bit
ND NC PT
RO
Bit
ND NC PT
RW
Txt
RW
Txt
RW
Txt
RW
Txt
RW
Txt
RO
Num ND NC PT
RW Num DE
RW Num DE
RW Num DE
RW Num DE
RW Num
RW
Txt
RO
Bit
ND NC PT
RW
Txt
RW Num DE
RW Num
RW Num
RW Num
RW Num
RW Num
RW Num
RO
Num DE
RO
Num DE
RO
Num DE
RO
Num DE
RW Num
Bin
Binary parameter
PS
Power-down save
UL Listing
US
US
US
US
US
PT
US
PT
US
PT
US
PT
US
PT
US
US
US
PT
US
US
US
US
US
US
US
PT
US
PT
US
PT
US
PT
US
PT
US
FI
Filtered
DE Destination
73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m101

Table of Contents