Safety
Product
Mechanical
information
information
installation
Figure 4-2 Default terminal functions
4.2.2
Control terminal specification
1
0V common
Function
2
Analog input 1
Default function
Type of input
Mode controlled by...
Operating in voltage mode (default)
Full scale voltage range
Maximum offset
Absolute maximum voltage range
Input resistance
Operating in current mode
Current ranges
Maximum offset
Absolute maximum voltage (reverse bias)
Absolute maximum current
Equivalent input resistance
Common to all modes
Resolution
Sample rate
4
+10 V user output
Default function
Nominal voltage
Voltage tolerance
Maximum output current
14
Electrical
Getting
Basic
installation
started
parameters
1
Analog
frequency
reference 1
At zero frequency
Drive enable
Run forward
Run reverse
Drive OK
Common connection for all external devices
Frequency reference
Unipolar single-ended analog voltage or unipolar current
Pr 07.007
0V to +10 V ±3 %
±30 mV
-18 V to +30 V relative to 0V
100 kΩ
0 to 20 mA ±5 %, 20 to 0 mA ±5 %,
4 to 20 mA ±5 %, 20 to 4 mA ±5 %
250 µA
-18 V to +30 V relative to 0V
25 mA
165 Ω
11 bits
4 ms
Supply for external analog devices
10.2 V
±3 %
5 mA
Running the
Optimization
NV Media Card
motor
14
41 42
0V common
1
2
4
+10 V
+24 V
9
10
11
12
13
Relay
41
(over-voltage
42
category II)
Unidrive M100 / M101 Control User Guide
Advanced
Diagnostics
UL Listing
parameters
Issue Number: 1