Emerson Unidrive M100 Control User Manual page 86

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M100:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Trip
HF02
Data processing error: CPU memory management fault
The HF02 trip indicates that a DMAC address error has occurred. This trip indicates that the control PCB on the drive has
failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF03
Data processing error: CPU has detected a bus fault
The HF03 trip indicates that a bus fault has occurred. This trip indicates that the control PCB on the drive has failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF04
Data processing error: CPU has detected a usage fault
The HF04 trip indicates that a usage fault has occurred.This trip indicates that the control PCB on the drive has failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF05
Reserved
HF06
Reserved
HF07
Data processing error: Watchdog failure
The HF07 trip indicates that a watchdog failure has occurred. This trip indicates that the control PCB on the drive has failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF08
Data processing error: CPU Interrupt crash
The HF08 trip indicates that a CPU interrupt crash has occurred. This trip indicates that the control PCB on the drive has
failed. The crash level is indicated by the sub-trip number.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF09
Data processing error: Free store overflow
The HF09 trip indicates that a free store overflow has occurred. This trip indicates that the control PCB on the drive has
failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF10
Reserved
HF11
Data processing error: Non-volatile memory comms error
The HF11 trip indicates that a non-volatile memory comms error has occurred. The crash level is indicated by the sub-trip
number. This trip indicates that the control PCB on the drive has failed.
Sub-trip
1
2
HF12
Data processing error: main program stack overflow
The HF12 trip indicates that the main program stack overflow has occurred. The stack can be identified by the sub-trip
number. This trip indicates that the control PCB on the drive has failed.
Recommended actions:
Hardware fault - Contact the supplier of the drive.
HF13
Reserved
HF14
Reserved
86
Electrical
Getting
installation
started
parameters
Reason
Non-volatile memory comms error.
EEPROM size is incompatible with the user
firmware.
Sub-trip
Derivative background stack overflow
1
Derivative timed stack overflow
2
Main system interrupt stack overflow
3
Main system background stack overflow
4
Basic
Running the
Optimization
motor
Diagnosis
Hardware fault – contact the supplier of the drive.
Contact the supplier of the drive.
Reason
Advanced
NV Media Card
Diagnostics
parameters
Recommended action
Unidrive M100 / M101 Control User Guide