Parameter
06.001
Stop Mode
06.002
Limit Switch Stop Mode
06.003
Supply Loss Mode
06.004
Start/Stop Logic Select
06.006
Injection Braking Level
06.007
Injection Braking Time
06.008
Hold Zero Frequency
06.009
Catch A Spinning Motor
06.010
Enable Conditions
06.011
Sequencer State Machine Inputs
06.012
Enable Stop Key
06.014
Disable Auto Reset On Enable
06.015
Drive Enable
06.016
Date
06.017
Time
06.018
Day Of Week
06.019
Date/Time Selector
06.020
Date Format
06.021
Time Between Filter Changes
Filter Change Required /
06.022
Change Done
06.023
Time Before Filter Change Due
06.024
Reset Energy Meter
06.025
Energy Meter: MWh
06.026
Energy Meter: kWh
06.027
Energy Cost Per kWh
06.028
Running Cost
06.029
Hardware Enable
06.030
Run Forward
06.031
Jog Forward
06.032
Run Reverse
06.033
Forward/Reverse
06.034
Run
06.035
Forward Limit Switch
06.036
Reverse Limit Switch
06.037
Jog Reverse
06.038
User Enable
06.039
Not Stop
06.040
Enable Sequencer Latching
06.041
Drive Event Flags
06.045
Cooling Fan control
06.046
Supply Loss Hold Disable
Input Phase Loss Detection
06.047
Mode
06.048
Supply Loss Detection Level
06.051
Hold Supply Loss Active
Motor Pre-heat
06.052
Current Magnitude
Output Phase Loss Detection
06.058
Time
Output Phase Loss Detection
06.059
Enable
06.060
Standby Mode Enable
66
Electrical
Getting
Basic
installation
started
parameters
Range
( )
OL
CoASt (0), rP (1), rP.dc I (2),
dc I (3), td.dc I (4), diS (5)
StoP (0) or rP (1),
diS (0), rP.StoP (1),
ridE.th (2)
0 to 6
0.0 to 150.0 %
0.0 to 100.0 s
Off (0) or On (1)
diS (0), EnAbLE (1),
Fr.OnLy (2), rv.OnLy (3)
0 to 4087
0 to 127
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
00-00-00 to 31-12-99
00:00:00 to 23:59:59
Sun (0), Non (1), tuE (2), UEd (3),
thu (4), Fri (5), SAt (6)
SEt (0), Po.uP (1), run (2),
Acc.Po (3)
Std (0), US (1)
0 to 30000 Hours
Off (0) or On (1)
0 to 30000 Hours
Off (0) or On (1)
±999.9 MWh
±99.99 kWh
0.0 to 600.0
±32000
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
0 to 3
0 to 5
Off (0) or On (1)
FuLL (0), rIPPLE (1), diS (2)
0 to VM_SUPPLY_LOSS_LEVEL V
Off (0) or On (1)
0 to 100 %
0.5 (0) to 4 (3) s
Off (0) or On (1)
Off (0) or On (1)
Running the
Optimization
NV Media Card
motor
Default
( )
OL
rP (1)
rP (1)
diS (0)
50 Hz: 0, 60 Hz: 4
100.0 %
1.0 s
Off (0)
diS (0)
Off (0)
Off (0)
On (1)
Po.uP (1)
Std (0)
0 Hours
Off (0)
0.0
Off (0)
Off (0)
Off (0)
Off (0)
Off (0)
Off (0)
Off (0)
Off (0)
Off (0)
Off (0)
Off (0)
0
2
Off (0)
FuLL (0)
110 V drive: 205 V
200 V drive: 205 V
400 V drive: 410 V
Off (0)
0 %
0.5 (0) s
Off (0)
Off (0)
Unidrive M100 / M101 Control User Guide
Advanced
Diagnostics
UL Listing
parameters
Type
RW
Txt
RW
Txt
RW
Txt
RW
Num
RW
Num
RA
RW
Num
RW
Bit
RW
Txt
RO
Bin
ND
NC
PT
RO
Bin
ND
NC
PT
RW
Bit
RW
Bit
RW
Bit
NC
RW
Date
ND
NC
PT
RW
Time ND
NC
PT
RO
Txt
ND
NC
PT
RW
Txt
RW
Txt
RW
Num
RW
Bit
ND
NC
RO
Num
ND
NC
PT
RW
Bit
RO
Num
ND
NC
PT
RO
Num
ND
NC
PT
RW
Num
RO
Num
ND
NC
PT
RO
Bit
NC
RW
Bit
NC
RW
Bit
NC
RW
Bit
NC
RW
Bit
NC
RW
Bit
NC
RW
Bit
NC
RW
Bit
NC
RW
Bit
NC
RW
Bit
NC
RW
Bit
NC
RW
Bit
RW
Bin
NC
RW
Num
RW
Bit
RW
Txt
RW
Num
RA
RW
Bit
NC
RW
Num
RW
Txt
RW
Bit
RW
Bit
Issue Number: 1
US
US
US
US
US
US
US
US
US
US
US
US
US
US
PS
PS
PS
US
US
US
US
US
US
US
US
US
US

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m101

Table of Contents