Emerson Unidrive M100 Control User Manual page 50

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M100:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
VM_POWER
Units
kW
Range of [MIN]
-9999.99 to 0.00
Range of [MAX]
0.00 to 9999.99
VM_POWER[MAX] is rating dependent and is chosen to allow for the maximum power that can be output by the drive
with maximum AC output voltage, at maximum controlled current and unity power factor.
Definition
VM_POWER[MAX] = √3 x VM_AC_VOLTAGE[MAX] x VM_DRIVE_CURRENT[MAX] / 1000
VM_POWER[MIN] = -VM_POWER[MAX]
VM_RATED_CURRENT
Units
A
Range of [MIN]
0.00
Range of [MAX]
0.00 to 9999.99
VM_RATED_CURRENT [MAX] = Maximum Rated Current (11.060) and is dependent on the drive rating.
Definition
VM_RATED_CURRENT [MIN] = 0.00
VM_SPEED_FREQ_REF
Units
Hz
Range of [MIN]
-550.00 to 0.00
Range of [MAX]
0.00 to 550.00
This variable minimum/maximum is applied throughout the frequency and speed reference system so that the
references can vary in the range from the minimum to maximum clamps.
Definition
VM_SPEED_FREQ_REF[MIN] = -VM_SPEED_FREQ_REF[MAX].
VM_SPEED_FREQ_REF_UNIPOLAR
Units
Hz
Range of [MIN]
0.00
Range of [MAX]
0.00 to 550.00
VM_SPEED_FREQ_REF_UNIPOLAR[MAX] = VM_SPEED_FREQ_REF[MAX]
Definition
VM_SPEED_FREQ_REF_UNIPOLAR[MIN] = 0.00
VM_SPEED_FREQ_USER_REFS
Units
Hz
Range of [MIN]
-550.00 to 550.00
Range of [MAX]
0.00 to 550.00
This variable maximum is applied to Analog Reference 1 (01.036) and Keypad Reference (01.017).
The maximum applied to these parameters is the same as other frequency reference parameters.
VM_SPEED_FREQ_USER_REFS [MAX] = VM_SPEED_FREQ_REF[MAX]
However the minimum is dependent on Negative Reference Clamp Enable (01.008) and Bipolar Reference Enable
(01.010).
Reference Clamp
Definition
50
Electrical
Getting
installation
started
parameters
Range applied to parameters that either set or display power
Range applied to rated current parameters
Range applied to the frequency reference parameters
Negative Reference Clamp Enable (01.008)
0
1
Unipolar version of VM_SPEED_FREQ_REF
Range applied to analog reference parameters
Negative
Bipolar Reference
Enable (01.010)
Enable (01.008)
0
0
0
1
1
0
1
1
Basic
Running the
Optimization
motor
Maximum Reference Clamp (01.006)
Maximum Reference Clamp (01.006) or |Minimum Reference
Clamp (01.007)| whichever the larger
VM_SPEED_FREQ_USER_REFS[MIN]
Minimum Reference Clamp (01.007)
-VM_SPEED_FREQ_REF[MAX]
0.00
-VM_SPEED_FREQ_REF[MAX]
Advanced
NV Media Card
Diagnostics
parameters
VM_SPEED_FREQ_REF[MAX]
Unidrive M100 / M101 Control User Guide