Emerson Unidrive M100 Control User Manual page 91

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M100:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Trip
P.dAt
Power system configuration data error
The P.dAt trip indicates that there is an error in the configuration data stored in the power system. This trip is generated
from within the drive control system or from the power system. The trip is related to the table uploaded from the power
system at power-up.
Source
Control
system
Control
system
Control
system
Control
system
Control
220
system
Control
system
Control
system
Power
system
Power
system
Power
system
Recommended actions:
Hardware fault – Contact the supplier of the drive
Pb.bt
Power board is in bootloader mode
Power board is in bootloader mode
245
Recommended actions:
Contact the supplier of the drive.
Pb.Er
Communication has been lost / errors detected between control and power processor
The Pb.Er trip is initiated if there is no communications between the control board processor and the power board
processor. The reason for the trip can be identified by the sub-trip number.
Sub-trip
93
Recommended actions:
Hardware fault – Contact the supplier of the drive
Pb.HF
Power board HF
Power processor hardware fault. The sub-trip number is the HF code.
Recommended actions:
235
Hardware fault - Contact the supplier of the drive
Pd.S
Power down save error
The Pd.S trip indicates that an error has been detected in the power down save parameters saved in non-volatile memory.
37
Recommended actions:
Perform a 1001 save in Pr mm.000 to ensure that the trip doesn't occur the next time the drive is powered up.
Unidrive M100 / M101 Control User Guide
Issue Number: 1
Electrical
Getting
installation
started
parameters
xx
y
00
0
00
0
00
0
00
0
00
0
00
0
0
0
01
0
01
0
01
0
1
PLL operating region out of lock
2
Power board lost communication with user board
3
User board lost communication with power board
4
Communication CRC error
Basic
Running the
Optimization
motor
Diagnosis
zz
01
No data was obtained from the power board.
02
There is no data table.
The power system data table is bigger than the space available in
03
the control pod to store it.
04
The size of the table given in the table is incorrect.
05
Table CRC error.
The version number of the generator software that produced the
06
table is too low.
07
The power data table failed to be stored in the power board.
The power data table used internally by the power module has an
00
error.
The power data table that is uploaded to the control system on
01
power up has an error.
The power data table used internally by the power module does
02
not match the hardware identification of the power module.
Reason
Advanced
NV Media Card
Diagnostics
parameters
Description
UL Listing
91