Emerson Unidrive M100 Control User Manual page 58

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M100:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Parameter
02.001
Post Ramp Reference
02.003
Ramp Hold
02.004
Ramp Mode Select
02.006
S Ramp Enable
Max Rate Of Change Of
02.007
Acceleration
02.008
Standard Ramp Voltage
Deceleration Fail Detection
02.009
Disable
02.010
Acceleration Rate Selector
02.011
Acceleration Rate 1
02.012
Acceleration Rate 2
02.013
Acceleration Rate 3
02.014
Acceleration Rate 4
02.015
Acceleration Rate 5
02.016
Acceleration Rate 6
02.017
Acceleration Rate 7
02.018
Acceleration Rate 8
02.019
Jog Acceleration Rate
02.020
Deceleration Rate Selector
02.021
Deceleration Rate 1
02.022
Deceleration Rate 2
02.023
Deceleration Rate 3
02.024
Deceleration Rate 4
02.025
Deceleration Rate 5
02.026
Deceleration Rate 6
02.027
Deceleration Rate 7
02.028
Deceleration Rate 8
02.029
Jog Deceleration Rate
02.030
Acceleration Rate Selected
02.031
Deceleration Rate Selected
02.032
Acceleration Rate Select Bit 0
02.033
Acceleration Rate Select Bit 1
02.034
Acceleration Rate Select Bit 2
02.035
Deceleration Rate Select Bit 0
02.036
Deceleration Rate Select Bit 1
02.037
Deceleration Rate Select Bit 2
02.039
Ramp Rate Units
02.040
S Ramp Percentage
02.041
S Ramp Set-up Mode
02.042
Maximum Rate Of Change Of Acceleration 1
02.043
Maximum Rate Of Change Of Acceleration 2
02.044
Maximum Rate Of Change Of Acceleration 3
02.045
Maximum Rate Of Change Of Acceleration 4
RW
Read / Write
RO
Read only
ND
No default value
NC
Not copied
Date
Date parameter
Time
Time parameter
58
Electrical
Getting
Basic
installation
started
parameters
Range ( )
VM_SPEED_FREQ_REF Hz
Off (0) or On (1)
FASt (0), Std (1), Std.bSt (2),
FSt.bSt (3)
Off (0) or On (1)
0.0 to 300.0 s²/100Hz
0 to VM_DC_VOLTAGE_SET V
Off (0) or On (1)
0.0 to VM_ACCEL_RATE s / 100 Hz
0.0 to VM_ACCEL_RATE s / 100 Hz
0.0 to VM_ACCEL_RATE s / 100 Hz
0.0 to VM_ACCEL_RATE s / 100 Hz
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
0 (s/100 Hz),
1 (s/Maximum Frequency),
2 (s/1000 Hz)
0.0 to 50.0 %
0.0 to 300.0 s²/100 Hz
0.0 to 300.0 s²/100 Hz
0.0 to 300.0 s²/100 Hz
0.0 to 300.0 s²/100 Hz
Num Number parameter
PT
Protected parameter
Running the
Optimization
NV Media Card
motor
Default ( )
OL
OL
Off (0)
Std (1)
Off (0)
3.1 s²/100 Hz
110 V drive: 375 V
200 V drive: 375 V
400 V drive 50
Hz: 750 V
400 V drive 60
Hz: 775 V
575 V drive: 895 V
690 V drive: 1075 V
Off (0)
0 to 9
5.0 s / 100 Hz
0.2 s / 100 Hz
0 to 9
10.0 s / 100 Hz
0.2 s / 100 Hz
0 to 8
0 to 8
Off (0)
Off (0)
Off (0)
Off (0)
Off (0)
Off (0)
0 (s/100 Hz)
0.0 %
0 to 2
0.0 s²/100 Hz
0.0 s²/100 Hz
0.0 s²/100 Hz
0.0 s²/100 Hz
Bit
Bit parameter
Txt
Text string
RA
Rating dependent
US
User save
Unidrive M100 / M101 Control User Guide
Advanced
Diagnostics
parameters
Type
RO
Num
ND
RW
Bit
RW
Txt
RW
Bit
RW
Num
RW
Num
RW
Bit
0
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
0
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RO
Num
ND
RO
Num
ND
RW
Bit
RW
Bit
RW
Bit
RW
Bit
RW
Bit
RW
Bit
RW
Num
RW
Num
0
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
Bin
Binary parameter
PS
Power-down save
Issue Number: 1
UL Listing
NC
PT
US
US
US
US
RA
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
NC
PT
NC
PT
NC
NC
NC
NC
NC
NC
US
US
US
US
US
US
US
FI
Filtered
DE Destination

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m101

Table of Contents