3 DESIGN

3.3 Layout Design within The Control Panel

3.3.1 Installation environment

Install the Motion controller system in the following environment conditions.
(1) Ambient temperature is within the range of following conditions.
Number of
Q173CPUN(-T)/
the Motion CPU
Q172CPUN(-T)
1
2 or more
(2) Ambient humidity is within the range of 5 to 95[%] RH.
(3) No condensing from sudden temperature changes
(4) No corrosive or inflammable gas
(5) There must not be a lot of conductible dust, iron filings, oil mist, or salt, organic
solvents.
(6) No direct sunlight
(7) No strong electrical or magnetic fields
(8) No direct vibrations or shocks on the Motion controller
With Cooling fan unit
(Shipped from the factory)
0 to 55°C (32 to 131 °F)
(Note-1) : It is need to install the Cooling fan unit(Q170FAN).
3 - 15
Q173CPU/Q172CPU
Without Cooling fan unit
0 to 40°C (32 to 104°F)
(Note-1)