Mitsubishi Electric Q173CPU User Manual page 94

Q series motion controller
Hide thumbs Also See for Q173CPU:
Table of Contents

Advertisement

2 SYSTEM CONFIGURATION
(3) Teaching unit specifications
Items
Language
Tact switch
ENABLE/DISABLE switch
Operation
Emergency stop switch
Deadman switch
Contrast adjusting switch
Display method
Interface
Protective construction
Ambient temperature
5VDC power supply
5VDC consumption current [A]
Mass [kg]
POINTS
(1) The total extended distance of cable between the Motion CPU and teaching
unit is within [30m(98.43ft.)] including the A31TU-D3 /A31TU-DN
[5m(16.40ft.)]
(2) The teaching unit is shipped, a protection sheet is attached in the surface of
the display and operation key to prevent the crack for conveyance. Remove a
protection sheet to use. Operation and display check without removing a
protection sheet are possible, however adhesives may remain in a teaching
unit by secular change.
(3) When the servomotor is operated by the JOG feed, etc. using the teaching unit
(A31TU-D3 ) with deadman switch, operate it pushing the deadman switch at
middle position. The emergency stop state of Motion CPU occurs by gripping
or releasing this switch, and the servomotor stops and becomes coasting
state.
(4) Connection between the teaching unit and Motion CPU
(a) Connection between the teaching unit (A31TU-D3 ) and
Motion CPU (Q173CPUN-T/Q172CPUN-T)
1) Connect the cable for teaching unit (Q170TUD3CBL3M) between the
TU connector of Motion CPU (Q173CPUN-T/Q172CPUN-T) and
control panel. (Refer to the exterior dimensions of "APPENDIX 1.3
Cable for the teaching unit" and "APPENDIX 2.7 Connector", when it is
fit to the control panel.)
2) Connect the connector for external safety circuit (connector for
emergency stop switch × 2 sets, connector for deadman switch × 2
sets and connector for emergency stop input to Motion CPU × 1 set) to
the external safety circuit.
3) Connect the teaching unit (A31TU-D3 ) to the cable for teaching unit
(Q170TUD3CBL3M) connected to the control panel.
A31TU-D3
3-position switch
4 lines × 16 characters LCD display
1.74 (Including cable 5m (16.40ft.))
2 - 75
Specifications
A31TU-DN
Japanese
28 keys for SV
Operation enable/disable
Push lock return reset type
None
Shade/light
Conforming RS-422
IP54 equivalent
0 to 40°C (32 to 104°F)
Supplied from Motion CPU
0.26
cable

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q173cpunQ172cpuQ172cpun

Table of Contents