Code
Modem not ready to receive V.34 data during 6 seconds after receiving CFR sig-
008F
nal.
0090
Called side document not ready for our polling.
Sending out DCS+TCF signal 3 times consecutively but no signal in response
0091
from receiver.
0092
Remote side disconnected during transmitting phase.
0093
Received DCN signal after sending out DCS signal for V.34.
0094
It is over 4 minutes to TX a ECM block (64K).
0095
Wrong ID number when Polling RX or Mail Box TX.
0099
Remote side disconnect after primary channel.
009A
Did not detect any signal after sending CI signal.
009C
Received DCN after sending DTC in V.34 polling RX.
Remote side hang up before V.34 modem enters phase B state in V.34 polling
009D
RX.
009F
Did not receive any response from other side after sending PPS_EOM signal.
00A0
User stops or cancels transmission job.
00A1
Document JAM during transmission.
Did not finish V.8 procedure or detect V.21 signal after CM signal within 30 sec-
00AE
onds.
Modem can not enter into control channel after TX side sends out RCP signal for
00AF
V.34.
00B0
Did not receive any command after our side retry three DCS signal in V.34 TX.
Did not finish V.8 procedure or detect V.21 signal after ANSam signal within 35
00B1
seconds.
00B2
Did not detect phase B signal after our side sending CJ signal within 30 seconds.
00B3
Did not detect correct V.21 or JM signal after sending CM signal.
Did not detect correct phase B signal within 25 second after CM/JM signal
00B4
exchange.
00B5
Did not detect phase C signal after phase B within 25 seconds.
00B6
Did not detect phase D signal within 25 seconds after CM/JM exchange.
00B7
Did not detect phase E signal after phase D within 30 seconds.
00B8
Remote side disconnect after our side sent DCS signal in V.34.
00B9
Receive T.30 signal other than DIS,DCS,CFR after sending DCS signal in V.34.
00BA
Did not receive correct signal after our side sent DTC signal in V.34.
00BB
Every time our side received DIS signal after sending DTC in V.34.
00BC Modem not ready within 10 second after entering primary channel in V.34.
00BD Can not detect correct V.21 or JM signal after detected FSK frequency.
00BE
Remote side no document to be polled after V8 handshaking.
00BF
Capability not match after V8 handshaking.
00C0
Remote side disconnect before entering primary channel in V.34.