(62) SOFT SWITCH: #60

Bit
Designation
No.
8
Reserved
7
Reserved
6
Quick memory TX
B4/ A3 declaration
5
for Ledger
The width of TX Led-
4
ger (8k)
Print mailbox RX
3
image even if pass-
word is not correct
Off hook alarm after
2
communication
Display destination
1
selection within TX
Phase C
• Bit 3: If bit 3 is set to "1", machine will print out the incoming page even if password is not
correct.

(63) SOFT SWITCH: #61

Bit
Designation
No.
8
Reserved
7
Reserved
6
Reserved
5
Reserved
4
3
2
Max. No. of rings
1
Function
Reserved
Reserved
0: Ineffective
1: Effective
0: A3 size
1: B4 size
0: A3 size
1: B4 size
0: No
1: Yes
0: Alarm
1: No alarm after communication
0: Local Name or telephone number
1: Display and report Remote telephone num-
ber
Function
Reserved
Reserved
Reserved
Reserved
No. of rings
1
2
3
Bit 4
0
0
0
Bit 3
0
0
0
Bit 2
0
0
1
Bit 1
0
1
0
No. of rings
9
10 11 12 13 14 15 16
Bit 4
1
1
1
Bit 3
0
0
0
Bit 2
0
0
1
Bit 1
0
1
0
S-154
Initial
Setting
Bit HEX
0
0
1
0
0
0
0
1
Initial
Setting
Bit HEX
0
0
0
0
1
4
5
6
7
8
0
0
0
0
0
1
0
1
1
1
1
1
1
0
0
1
1
1
0
1
0
1
1
1
1
1
1
1
0
1
1
1
1
1
0
0
1
1
1
0
1
0
1
2
1
0
F