(36) SOFT SWITCH: #36

Bit
Designation
No.
Re-dial attempts
8
continue fail counter
7
Reserved
6
Reserved
5
Reserved
4
3
2
Re-dial attempts fail
limitation counter
1
• Bit 8: The redial fail counter will plus 1 for each auto dialing, unless user interruption or
after finish communication. If the counter is over the setting in bit 1~4 and Bit set to
1, then the machine will stop redial unless user interruption or enter the communi-
cation phase.
Function
0: No any limitation
1: limit up to bit 1 to 4
Reserved
Reserved
Reserved
Counter
0
1
2
Bit 4
0
0
0
Bit 3
0
0
0
Bit 2
0
0
1
Bit 1
0
1
0
Counter
8
9
10 11 12 13 14 15
Bit 4
1
1
1
Bit 3
0
0
0
Bit 2
0
0
1
Bit 1
0
1
0
S-137
Initial
Setting
Bit HEX
1
0
0
0
1
3
4
5
6
7
0
0
0
0
0
0
0
1
1
1
1
1
1
0
0
1
1
1
0
1
0
1
1
1
1
1
1
0
0
1
1
1
1
1
0
0
1
1
1
0
1
0
1