SMP Expansion Port cabling for one server with two SMP Expansion
Modules: Complete the following steps to cable two SMP Expansion Modules in a
single server together, using the two 25.4 cm (10 in.) SMP Expansion cables, for up
to 8-way operation. In the illustration, the SMP Expansion Modules are numbered 0
and 1, from bottom to top. The SMP Expansion Ports are numbered 1 through 3,
left to right. If your server comes with two SMP Expansion Modules, the SMP
Expansion cables are included with the server. If you purchased a second SMP
Expansion Module, the cables are included with the option.
Figure 33. SMP Expansion Module numbering
1. Remove the protective covers from the connectors on the ends of the cables.
Figure 34. SMP Expansion cable with protective cover
2. Connect one end of a 25.4 cm (10 in.) SMP Expansion cable to port 1 of SMP
3. Connect one end of the second 25.4 cm (10 in.) SMP Expansion cable to port 2
4. If you are connecting an RXE-100 enclosure, go to "RXE Expansion Port
36
xSeries 445 Type 8870: Installation Guide
1
1
2
3
0
1
2
3
Protective cover
Expansion Module 0; then, connect the opposite end of the cable to port 1 of
SMP Expansion Module 1.
of SMP Expansion Module 0; then, connect the opposite end of the cable to
port 2 of SMP Expansion Module 1.
cabling for one server with two SMP Expansion Modules" on page 43. If you are
not connecting an RXE-100 enclosure, connect all remaining external cables to
the server; then, go to "Creating a scalable partition" on page 63 and follow the
instructions for creating a scalable partition.
Notes:
1. When multiple cables are connected between the SMP Expansion Module
ports, SMP data is interleaved between the cables for better performance.
2. The server will start and operate with one cable attached between the two
SMP Expansion Modules.