Panasonic VL-V900 Installation And Operating Instructions Manual page 48

Video intercom system for apartment complexes vl-v900 and vl-v700 series
Hide thumbs Also See for VL-V900:
Table of Contents

Advertisement

5. Programming
Parameter
ZOOM POSITION
SET POWER FREQ.
SET CAMERA SIGNAL
SET TIME&DATE
SET TIME OUT
MONITOR TIME OUT
TALK TIME OUT
SET LIFT
SIGNAL MODE TO LIFT
SIGNAL TIME TO LIFT
SET ACCESS CODE
48
Description and available settings
Determines the camera zoom position.
[01]: UPPER LEFT
[02]: UPPER SIDE
[03]: UPPER RIGHT
[04]: LEFT
[05]: CENTRE
[06]: RIGHT
[07]: LOWER LEFT
[08]: LOWER SIDE
[09]: LOWER RIGHT
Tells the system what frequency of power is supplied
to the lobby station.
[00]: 50 HZ
[01]: 60 HZ
Tells the system what signal format is used by the
external camera.
[00]: PAL
[01]: NTSC
Determines the system's time and date settings.
Determines the amount of time that passes when
watching camera images before the standby screen is
displayed.
[00]: 180 SEC
[01]: 90 SEC
[02]: 60 SEC
[03]: 30 SEC
Determines the amount of time that passes when
talking before the standby screen is displayed.
[00]: 90 SEC
[01]: 60 SEC
[02]: 30 SEC
[03]: 180 SEC
[04]: 300 SEC
Determines the signalling method used by the lift
controller to communicate with the lift. Select the signal
type according to the specifications of the lift.
[00]: RELAY
[01]: BINARY
After a visitor is admitted, this setting determines the
amount of time that the visitor can use the lift to visit the
corresponding floor.
If the lift has a similar setting, set this parameter to any
value other than "0"; the lift's box setting will take
priority.
(001–900 SEC, or 000 to disable)
Determines the access code that allows you to use
lobby stations to configure the system.
(6 digits)
Default
05
(CENTRE)
00
(50 HZ)
00
(PAL)
1/JAN/2015
00:00
00
(180 SEC)
00
(90 SEC)
00
(RELAY)
300
(300 SEC)
123456

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vl-v703Vl-v702Vl-v700Vl-v701

Table of Contents