4. Installation
Repeater mode example
Up to 20
Control box
Distribution box
A
B
C
D
*4
Repeater mode
E
F
G
*1 Each DIP switch setting can only be used one time per branch.
The number 8 switch must always be set to the "off" position.
Only one DIP switch is set to the "on" position. All others are set to the "off" position.
*2 In repeater mode, the repeat switch of one distribution box in the branch is set to the "on" position. All others are
set to the "off" position.
Only one distribution box per branch can be used in repeater mode.
Main monitors cannot be connected to a distribution box that is set to repeater mode.
*3 The terminate switch of the last distribution box in the branch is set to the "on" position. All others (except for a
distribution box that is operating in repeater mode) are set to the "off" position.
*4 The distribution box functioning in repeater mode can be located between the control box and a distribution box,
or between 2 distribution boxes.