5. Programming
4
Open the desired configuration file.
R Use a third-party text editor or spreadsheet program to open the configuration file.
5
Change the values in the [Data] column as desired, and then save the file.
R Acceptable values are explained in the [Data Note] column.
R Descriptions of each setting and other information are explained in the [Item Note] column.
R See 5.2.10 List of PC programming parameters (Page 42) for information about each parameter.
6
Using the setup tool, click [Check Files] the [Prepare the data] section.
R The paths of each configuration file are displayed in the [Load and edit the data] section.
7
In the [Load and edit the data] section, click [Load / Edit ...] next to a configuration file that you want to upload.
R The files's details are displayed.
8
Click [Close].
9
Repeat from step 7 for each configuration file that you want to upload.
R Files that are ready to be uploaded are indicated by [OK] displayed in the right side of the [Load and edit the
data] section.
10
In the [Upload the data to device] section, select the devices that you want to upload the data to and then click
[Upload].
5.2.7 Setting the control box's date and time
1
Start the setup tool.
2
In the [Time and date settings] section, click [Time and Date Settings (Control Box)].
3
Set the date and time, and then click [Set to Control Box].
5.2.8 Configuring the main monitors
After you have configured the settings in the [Control Box — Room settings], use the following procedure to apply
these settings to the main monitors.
1
Start the setup tool.
2
In the [Connection check] section, click [Check Main Monitor (Set General Data)], and then click [Execute].
5.2.9 Confirming the control box's connection to the lift controllers
1
Start the setup tool.
2
In the [Connection check] section, click [Check Lift Controller].
5.2.10 List of PC programming parameters
The following parameters are available when using PC programming.
Control Box — Room settings
Parameter
Room No.
Floor No.
Lift access permission (Lift 1–3)
42
Description and available settings
Determines the room number of the main monitor
connected to the corresponding control box port,
distribution box number, and distribution box port.
(1–99999; 0 is displayed when the room is not
configured)
Determines the floor number setting of the
corresponding room number.
(0–99; 0 is the ground floor)
Determines which lifts can be used by visitors to each
lobby station.
Default
0
0
(No lifts can be
used)