5. Programming
Parameter
Terminal 1–4 Reception Code
Emergency Terminal Extension
Number
Emergency Terminal Emergency
Mode
Lobby Station 1–3 — Room settings
Parameter
Room No.
Resident Name
Lobby Station 1–3 — General settings
Parameter
Door Key Open Time
Door Key Out Signal
Door Key Open Code
Door Key External In
Door Key In Signal
Camera Connection
44
Description and available settings
Determines whether terminal 1–4 is a reception
terminal or a normal terminal (i.e., cannot be used as a
reception terminal).
[0]: NORMAL TERMINAL
[1]: RECEPTION TERMINAL
Tells the system the extension number for the
emergency terminal.
(24 digits max.)
Determines whether the emergency terminal can talk
to residents during an emergency call (emergency talk
mode) or if the emergency terminal receives an
announcement only (emergency notice mode).
[0]: EMERGENCY TALK
[1]: EMERGENCY NOTICE
Description and available settings
Determines the room number.
(1–99999; 0 is displayed when the room is not
configured)
Determines the resident name for the corresponding
room number.
(20 characters max., uppercase letters only)
Description and available settings
Determines the amount of time the door stays open. If
set to 0 SEC, the door cannot be opened.
(1–20 SEC, or 0 to disable)
Determines whether the signal sent to the electric lock
is a closed signal (i.e., the signal is normally open) or
an open signal (i.e., the signal is normally closed).
[0]: CLOSE
[1]: OPEN
Determines the door open code. If disabled, the door
cannot be opened using a code.
(4 digits, or #### to disable)
Tells the system whether an access controller (door
opener, key switch, card reader, etc.) is connected to
the lobby station and used to unlock the door.
[0]: NO
[1]: YES
Determines whether the signal received from the
access controller is a closed signal (i.e., the signal is
normally open) or an open signal (i.e., the signal is
normally closed).
[0]: CLOSE
[1]: OPEN
Tells the system whether a camera is connected or not.
[0]: NO
[1]: YES
Default
0
(NORMAL
TERMINAL)
0
(EMERGENCY
TALK)
Default
Default
5 SEC
0
(CLOSE)
####
(DISABLE)
0
(NO)
0
(CLOSE)
0
(NO)